THE
CONFIGURATION OF THIS SYSTEM IS DESIGNED
TO
SUIT IN BOTH RESIDENTIAL AND
COMMERCIAL
eNVIRONMENT.
SUCH
AS RESTAURANT, CAFE, SHOPS AND WORKSHOPS WITH HIGH TRAFFIC
Model WMMS-60CH-V2B(59)4/5X09EW
Function
Description
YMGI Smart Technologies
·
Auto-Restart After a power cut the unit will restart automatically with the previous function setting when the power returns.
·
Intelligent Auto-Defrosting The
unit can enter or quit the defrosting mode automatically by timely
detecting the frosting situation of the outdoor unit.
·
Sleep Mode Because
our body temperature cools down as we sleep, the unit automatically adjusts the
setting for all-night comfort.
·
Air Purifying and Deodorizing Filters Industrial
development has offered from one side a better life style, but on the other
side, it has increased polluting substances presence in the air that helps in
spreading of various kinds of diseases. Among the polluting agents, the ones we
can more frequently find at home are anti-bacterial dust particles, moulds and
etc, which are causing allergic phenomenon, breathing and typical upper
respiratory problems. This dual washable filter screen is effective in
preventing anti-bacteria mould and duct particles and ensuring a healthy indoor
environment.
·
Turbo Mode This
function enables the unit to reach the preset temperature in the shortest time.
·
Self-diagnosis and Auto-Protection Function This
function can electronically detect the errors and display the diagnosis by a
series of flashing LEDs on the indoor unit. Then the unit will automatically
switch to protection mode.
IMPORTANT NOTES ABOUT
THE DC INVERTER SYSTEM VARIOUS PERFORMANCES
·
The
rated performance data printed on the nameplate were tested per AHRI 210/240
standards at standard indoor & outdoor conditions and standard installation
set-up.
·
Actually
the DC inverter outdoor unit could modulate to match whatever capacity needs
are called/requested from indoor side, to produce a wide range of capacities,
minimum could be about 15% of the rated number and maximum could be around 160%
of the rated number.
·
Once the DC inverter system is installed, each indoor unit's output and so the outdoor unit performance will all vary over the operation period soft starting, turbo quick cooling/heating, maintaining, defrosting, switching, and other condition changes.
·
Actual
performance varies upon many factors such as indoor and outdoor temperatures,
inter-connecting pipe length/ bending, elevation difference between indoor and
outdoor units, refrigerant charging level, vacuum level, leakage, air or
moisture or contamination level, foreign substance left in the piping, indoor
filter clean level, indoor and outdoor coil conditions, and other factors.
·
When
the rated total capacity of all the indoor units exceeds the rated capacity of
outdoor unit, each indoor unit may not output the rated capacity and one may
differ from other, upon other installation/operation factors, it all units are
turned on to run compressor simultaneously.
PIPE ADAPTER
·
Whenever
the outdoor unit gas valve of size 3/8" is to connect with indoor unit gas
pipe of 1/2" or 5/8", one 3/8" - 1/2" or 3/8" -
5/8" adapter is to be used in between. This reducer is packed
separately and shall be installed at job site.
·
Any
indoor unit is 30' or more apart from the outdoor unit, better to adjust
refrigerant. If it is 50' or more apart, better to upper size the copper lines
and adjust refrigerant.
·
Any
run cannot be more than 100' apart from the outdoor unit; otherwise, that
indoor unit capacity may be reduced
Specification
BTU / Area Coverage Guide
* Cover area is a guide only, other factors should also take into consideration such as ceiling height, number of windows and wall material those affect insulation.
What area does this package system will cover
Approx 1750 Sqft
* Cover area is a guide only, other factors should also take into consideration such as ceiling height, number of windows and wall material those as affect insulation. Please check with your installer before to make sure this system is sufficient and suite your home.
Application
Warranty
All YMGI products come with standard 7 years limited warranty for compressor and 2 year limited warranty of parts for indoor units and installation kit. If you have any questions related to the operation of your equipment you are always welcome to contact us by email or phone and we will there to assist. Our contact information will be available in the warranty certificate.
YMGI does not provide installation
for equipment. Customer will need to hire a licensed HVAC technician and
install the equipment in a professional manner.
Installation by unlicensed personnel
will automatically void YMGI standard warranty and it is strongly not
recommended as it may cause danger to your property. YMGI and bizlander cannot
be held liable for any damage that caused by improper installation. Please be advised that federal law prohibits opening any
refrigeration line by anyone not properly licensed.
Please be noted returned warranty
certificate will be deemed as valid only if it is signed, dated and noted with
details of technician which responsible for the installation.
Payment
Paypal is our payment method by default. Please contact us if you require credit card payment.
Disclaimer
YMGI endeavour to ensure all information given here (include technical data, and other information) is correct. However due to omissions, errors and out-of-date data from constant improvement, YMGI and bizlander reserve all rights to modify any part of the content without notice. Every reasonable effort has been made to ensure all information contained here is correct.