| Product characteristics |
|---|
| Laser protection class | 2 |
| Housing | rectangular |
| Electrical data |
|---|
| Operating voltage [V] | 18...30 DC; (cULus - Class 2 source required) |
| Current consumption [mA] | < 150 |
| Protection class | III |
| Reverse polarity protection | yes |
| Typ. lifetime [h] | 50000 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2; Number of analog outputs: 1 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Max. current load per output [mA] | 200 |
| Number of analog outputs | 1 |
| Analog current output [mA] | 4...20; (IEC 61131-2) |
| Max. load [Ω] | 250 |
| Analog voltage output [V] | 0...10; (IEC 61131-2) |
| Min. load resistance [Ω] | 5000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Monitoring range |
|---|
| Max. light spot width [mm] | 15 |
| Max. light spot height [mm] | 15 |
| Light spot dimensions refer to | 10 m |
| Background suppression [m] | 0...19 |
| Measuring/setting range |
|---|
| Measuring range [m] | 0.2...10; (white paper 200 x 200 mm 90 % remission) |
| Sampling rate [Hz] | 1...50 |
| Interfaces |
|---|
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
| SIO mode | yes |
| Required master port class | A |
| Process data analog | 2 |
| Process data binary | 3 |
| Min. process cycle time [ms] | 6 |
| Supported DeviceIDs | | Type of operation | DeviceID | | default | 806 |
|
| Operating conditions |
|---|
| Ambient temperature [°C] | -10...60 |
| Protection | IP 67 |
| Tests / approvals |
|---|
| EMC | |
| Laser protection class | 2 |
| Notes on laser protection | | Caution: | Laser light | | Power: | <= 4 mW | | Wave length: | 650 nm | | pulse: | 1,3 ns | | Do not stare into beam. | | | Avoid exposure to the laser light. | | | laser class: | 2 | | EN / IEC60825-1:2007 | | EN / IEC60825-1:2014 | | Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
|
| MTTF [years] | 182 |
| Mechanical data |
|---|
| Weight [g] | 303 |
| Housing | rectangular |
| Dimensions [mm] | 59 x 42 x 52 |
| Material | housing: diecast zinc; front lens: glass; LED window: PC |
| Lens alignment | Side sensing |
| Displays / operating elements |
|---|
| Display | | Switching status | 2 x LED, yellow | | Power | LED, green | | Distance, programming | alphanumeric display, 4-digit |
|
| Accessories |
|---|
| Accessories (optional) | |
| Remarks |
|---|
| Remarks | | For more information about the measuring range / application please refer to the operating instructions. |
|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12 |
| Other data |
|---|
| Parameter | Setting range | Factory setting | | Uni | mm, m, inch | mm | | OU1 | Hno, Hnc, Fno, Fnc | Hno | | SP1 [mm] | 200...9999 | 1000 | | nSP1 [mm] | 200...9999 | 800 | | FSP1 [mm] | 200...9999 | 1200 | | OU2 | Hno, Hnc, Fno, Fnc, I, U | I | | SP2 [mm] | 200...9999 | 2000 | | nSP2 [mm] | 200...9999 | 1800 | | FSP2 [mm] | 200...9999 | 2200 | | ASP [mm] | 0...9999 | 0 | | AEP [mm] | 0...9999 | 9999 | | rATE [Hz] | 1...50 | 50 | | dS1 [s] | 0...0.1...5 | 0 | | dr1 [s] | 0...0.1...5 | 0 | | dS2 [s] | 0...0.1...5 | 0 | | dr2 [s] | 0...0.1...5 | 0 | | dFo [s] | 0...0.1...5 | 0 | | dIS | d1...3 ; rd1...3; OFF | d3 |
|
| Repeatability / Accuracy |
|---|
| read/write distance (mm) | Repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 200...1000 mm | ± 5.0 mm | ±7.5 mm | ± 15.0 mm | ± 18.0 mm | | 1000...2000 mm | ± 5.5 mm | ±10.0 mm | ± 15.0 mm | ± 20.0 mm | | 2000...4000 mm | ± 17.5 mm | ±22.5 mm | ± 25.0 mm | ± 32.0 mm | | 4000...6000 mm | ± 27.5 mm | ±40.0 mm | ± 35.0 mm | ± 50.0 mm | | 6000...10000 mm | ± 60.0 mm | | ± 70.0mm | |
|
| Sampling rate | 50 Hz | | Extraneous light on the object | < 40 klx |
|
| Repeatability / Accuracy |
|---|
| read/write distance (mm) | Repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 200...1000 mm | ± 16.5 mm | ±16.5 mm | ± 26.5 mm | ± 26.5 mm | | 1000...2000 mm | ± 16.5 mm | ±16.5 mm | ± 26.5 mm | ± 26.5 mm | | 2000...4000 mm | ± 30.0 mm | ±37.0 mm | ± 40.0 mm | ± 47.0 mm | | 4000...6000 mm | ± 37.0 mm | ±57.0 mm | ± 47.0 mm | ± 67.0 mm | | 6000...10000 mm | ± 75.0 mm | — | ± 85.0mm | — |
|
| Sampling rate | 50 Hz | | Extraneous light on the object | 40...100 klx |
|
| Repeatability / Accuracy |
|---|
| read/write distance (mm) | Repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 200...1000 mm | ± 4.0 mm | ±4.5 mm | ± 14.0 mm | ± 15.0 mm | | 1000...2000 mm | ± 4.5 mm | ±6.0 mm | ± 14.5 mm | ± 16.0 mm | | 2000...4000 mm | ± 13.5 mm | ±14.5 mm | ± 23.5 mm | ± 24.0 mm | | 4000...6000 mm | ± 19.0 mm | ±21.0 mm | ± 29.0 mm | ± 31.0 mm | | 6000...10000 mm | ± 37.0 mm | – | ± 47.0mm | – |
|
| Sampling rate | 1 Hz | | Extraneous light on the object | < 40 klx |
|
| Repeatability / Accuracy |
|---|
| read/write distance (mm) | Repeatability of the measured values | | Accuracy | | | white (90 % remission) | grey (18 % remission) | white (90 % remission) | grey (18 % remission) | | 200...1000 mm | ± 10.0 mm | ± 10.0 mm | ± 20.0 mm | ± 20.0 mm | | 1000...2000 mm | ± 10.0 mm | ± 10.0 mm | ± 20.0 mm | ± 20.0 mm | | 2000...4000 mm | ± 17.0 mm | ± 18.0 mm | ± 27.0 mm | ± 28.0 mm | | 4000...6000 mm | ± 22.0 mm | ± 25.0 mm | ± 32.0 mm | ± 35.0 mm | | 6000...10000 mm | ± 37.0 mm | – | ± 47.0mm | – |
|
| Sampling rate | 1 Hz | | Extraneous light on the object | < 40...100 klx | | - | - | | Range on black object (6 % remission) | <= 4000 mm | | - | - | | The values apply at | | | constant ambient conditions | 23 °C / 960 hPa | | minimum power-on time in minutes | 10 |
|