TeSys K, differential thermal overload relay, 1.8 to 2.6 A, class 10A



Main
rangeTeSys
product nameTeSys LRK
Product or Component TypeDifferential thermal overload relay
device short nameLR2K
relay applicationMotor protection
Product CompatibilityLP4K
LC1K
LC7K
LP1K
network typeDC
AC
thermal overload classClass 10A IEC 60947-4-1
thermal protection adjustment range1.8…2.6 A
[Ui] rated insulation voltagePower circuit 690 V BS 4941
Power circuit 690 V IEC 60947
Power circuit 750 V VDE 0110 group C
Power circuit 600 V CSA C22.2 No 14
Complementary
Network Frequency<= 400 Hz
mounting supportUnder contactor
Plate, with specific accessories
Rail, with specific accessories
auxiliary contact composition1 NO + 1 NC
[Ith] conventional free air thermal current6 A signalling circuit
[Ue] rated operational voltage<= 690 V power circuit
690 V AC AC-15 signalling circuit
250 V DC DC-13 signalling circuit
associated fuse rating6 A gG signalling circuit VDE 0660
6 A gG signalling circuit IEC 60947
[Uimp] rated impulse withstand voltage6 kV
power dissipation per pole2 W
phase failure sensitivityYes IEC 60947-4-1
local signallingTrip indicator Yellow)
control typeRed push-button trip test function
Blue push-button stop and manual reset
selector switch manual or automatic reset
connections - terminalsScrew clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
tightening torque11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2
11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
11.51 lbf.in (1.3 N.m) screw clamp terminals pozidriv No 2
Height2.28 in (58 mm)
Width1.77 in (45 mm)
Depth2.56 in (65 mm)
Net Weight0.32 lb(US) (0.145 kg)
Environment
standardsBS 4941
VDE 0660
IEC 60947
NF C 63-650
Product CertificationsUL
CSA
UKCA
protective treatmentTC IEC 60068
TC DIN 50016
IP degree of protectionIP2x conforming to IEC 60529
ambient air temperature for operation-4…131 °F (-20…55 °C) without derating IEC 60947
-22…140 °F (-30…60 °C) with derating IEC 60947
Ambient Air Temperature for Storage-40…158 °F (-40…70 °C)
operating altitude6561.68 ft (2000 m) without derating
fire resistance1562 °F (850 °C) IEC 60695-2-1
flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
mechanical robustnessShocks NO contact10 Gn for 11 ms IEC 60068-2-27
Shocks NC contact10 Gn for 11 ms IEC 60068-2-27
Vibrations NO contact2 Gn, 5...300 Hz IEC 60068-2-6
Vibrations NC contact2 Gn, 5...300 Hz IEC 60068-2-6


Information on this page is provided to the best of our knowledge, if you have any questions, please contact us before bidding.

*****IF YOU NEED ADDITIONAL PICTURES, PLEASE SEND US AN E-MAIL WITH WHAT YOU WOULD LIKE PHOTOS OF AND THE E-MAIL ADDRESS TO SEND THEM TO. *****

THIS IS BEING SOLD AS-IS WHAT YOU SEE IN THE PICTURE IS WHAT YOU WILL BE GETTING. PLEASE DO NOT ASSUME THERE IS MORE TO IT. IF YOU ARE UNCERTAIN, PLEASE BE SURE TO ASK PRIOR TO BIDDING

WAIVER LIABILITY AND INDEMNIFICATION AGREEMENT

By placing this order with THE SELLER of this sale and accepting the parts, the purchaser agrees that the purchased materials or parts will be used solely at the purchaser's risk and that the purchaser will indemnify and hold THE SELLER, its owners and employees, free and harmless from all loss, liability and damage resulting from claims brought by any regulatory agencies, or by reason of any alleged failure or defect of any parts supplied by THE SELLER.



IF THERE IS A MAJOR DISCREPANCY OR BLATANT MISREPRESENTATION, WE WILL BE MORE THAN HAPPY TO DISCUSS THE ISSUE WITH YOU.



There are ALWAYS additional shipping charges to Puerto Rico, Hawaii, and Alaska. Please ask these charges prior to bidding if this is going to be a problem. We always take the up most care in packing to make sure that your item arrives to you in the condition it left herewith no damage.
Thank you for looking and happy browsing!

If for any reason you feel you haven’t received “5-Star” customer service, please let me know what we did wrong and what we can do to correct it, so it doesn't happen again.

We do our best to describe each and every piece of equipment but depend on our bidders to know exactly what they are bidding on. All of our medical equipment listings have come from hospital closures or hospitals and clinics that have recently upgraded their equipment. The majority of this equipment is from large companies or government offices and hospitals. Most equipment is in good working order but still needs to be checked out before putting into use. All items are sold as is unless stated otherwise in the above description. No returns accepted unless the item is found to be not as we described in this ad. Contact us first before returning anything as you will need a return authorization number. If you do not contact us first, no credit will be issued no matter what the issues are.