HDP135V6 power supply is a high-quality, cost-effective and economical DC regulated power supply.
Four-digit LED voltage and current display.
It has the functions of over voltage protection (OVP), over current protection (OCP), over temperature protection (OTP) and USB fast charging.
|
Type |
CH |
OutPut V/A |
LCD Points |
RS232 |
|
HDP135V6 |
1 |
35V/6A |
4 |
No |
|
HDP135V6S |
1 |
35V/6A |
4 |
Yes |
1 Working Condition
AC input:115 VAC ± 10%,230 VAC ± 10%,50/60Hz
Working conditions: temperature -10℃~40℃, relative humidity ≤80%
Storage conditions: temperature -20℃~60℃, relative humidity ≤80%
2 Specification
Remark: All technical indicators can only be guaranteed when the instrument has been continuously operated for more than 30 minutes at the specified operating temperature (18°C to 28°C).
| Voltage | |
| Load regulation rate | ≤0.1% + 5mV |
| Linear adjustment rate | ≤0.01% + 5mV |
| resolution | 10mV |
| accuracy | ≤0.1% + 1 digits |
| Readback resolution | 10mV |
| Readback accuracy | ≤0.1% + 1 digits |
| Ripple | 10mVrms |
| Current | |
| Load regulation rate | ≤0.2% + 3mA |
| Linear adjustment rate | ≤0.2% + 3mA |
| resolution | 1mA |
| accuracy | ≤0.2% + 3mA |
| Readback resolution | 1mA |
| Readback accuracy | ≤0.2% + 3 digits |
| Ripple | 5mArms |
| Overvoltage protection OVP | 0 ~ 32V ± 0.2%FS |
| Maximum voltage | 35V ± 0.2% |
| Overcurrent protection OCP | 0 ~ 6A ± 0.2%FS |
| Maximum current | 6A ± 0.2% |
| Fast Charge | |
| Output V | 5V ~ 12V |
| Output W | MAX18W |
| fast charge protocol | DCP(Apple、Samsung & BC1.2)、Qualcomm QC2.0/QC3.0、Huwei FCP、SamsungAFC |
| Others | |
| Remote interface | RS232 (optional) |
| Baud rate: 2400 | |
| Data bits: 8 | |
| Stop bit: 1 | |
| No parity | |
| AC input | 115 Vac ± 10%,230 Vac ± 10%,50/60Hz |
| Working conditions | temperature -10℃ ~ 40℃,humidity≤80% |
| Storage conditions | temperature -20℃ ~ 60℃,humidity≤80% |
| Cooling method | Air-cooled |
| weight | 2.2Kg |
| size | 85×150×230(mm) |
Package:
1 set power supply.