Product Details

Feature
The high-brightness digital tube clearly displays, whether it is used during the day or at night, it can be read clearly
The sensor can be replaced at will by using the 2P terminal. When you need to use other probes, you can replace it at will
ABS material shell, exquisite and beautiful, high mechanical strength, good electrical performance, anti-aging
-50~110℃ ultra-wide temperature control range, can be used in various temperature control fields, 0.1℃ temperature control accuracy, to meet your control needs
Wiring input and output design, more convenient to use in various industrial control equipment, multi-strand wire 300V/20A excess configuration, safe and reliable
Specification
Product name: Microcomputer temperature controller
Product Model::XH-W3002
Temperature measurement range: -50~110℃
Temperature control range: -50~110℃
Temperature measurement accuracy: ±0.2℃
Temperature control accuracy: ±0.1℃
Measurement input: NTC10K L=1 meter waterproof probe
Input power: 12/24/220V
Output power: 120/240/1500W
output type: direct output
Output capacity: max 10A
Installation hole distance: 73mm (diameter 4mm)
Appearance size: 60*45*31mm
Set using
Code and function introduction
P0 set startup temperature
Press the setting button once to enter the internal menu, the default display is P0, press the setting button again, and set the required startup temperature by pressing the up and down buttons.
P1 set stop temperature
Press the setting button once to enter the internal menu, the digital display is P0, switch to P1 by pressing the up and down buttons, press the setting button again, and set the desired stop temperature by pressing the up and down buttons.
P2 Set temperature correction
Enter the internal menu in the same way, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration temperature by pressing the up and down buttons. In the setting, if the detected temperature value is 0.5°C higher than the actual temperature value, the calibration temperature to be set is -0.5°C. If the detected temperature value is 1°C lower than the actual temperature value, the calibration temperature to be set is 1°C. Detected temperature±corrected temperature=actual temperature.
P3 set delay start
Enter the internal menu in the same way, switch to P3 by pressing the up and down keys, press the setting key again, and set the required delay time (unit is minutes) by pressing the up and down keys. Delay start is generally used for compressor refrigeration. If it is used for refrigerator freezers, this value needs to be set. According to the size of the compressor back pressure, the general setting value is 3-6 minutes. If you are not used to control the compressor or do not need delay time function, skip this item directly.
List
1 x Thermostat
  • Payment must be received in 5 business days of auction closing.
  • Please leave note for your special request (e.g. Colors or Size) when you pay the order.
  • Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.

1. We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
2. Orders will be processed instantly and dispatched within 1-3 business days except hoilday, so we do NOT accept any email/message note after you place orders.
3. All package need to wait 30 days,Please take care it.Less than 30 days,we can't take a refund.

We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.