1 Digit WH-8AL Coating Thickness Gauge Paint Thickness Tester F-Type Probe

This device is a portable meter. It is capable of measuring coating thickness quickly, precisely and without injury, both for the laboratory and engineering environment. It is currently widely used in 


manufacturing, metal processing industry, chemical industry, commodity inspection and testing fields, and is essential for material protection major.


This device meets the following criteria:

GB/T 4956─1985 non-magnetic coating thickness measurement on magnetic metal substrate, Magnetic Method

GB/T 4957─1985 non-conductive coating thickness measurement on non-magnetic metal substrate, Eddy Current Method

JB/T 8393-1996  Magnetic & Eddy Current coating thickness measurement

 

Features

Thickness measurement using both Magnetic Method to measure the non-magnetic coating on a magnetic metal substrate and Eddy Current Method to measure the non-conductive coating on a

non-magnetic metal substrate.

Single-point or two-point method could be used to correct probe system deviation, in order to ensure the accuracy of the device in the process of measuring.

Automatic identify ferrous and non-ferrous substrate quickly.

Power voltage indicator.

Speaker beep while operating.

Power-off automatically when idle; manually power-off available.

Negative display function to ensure the accuracy of zero point calibration.

Showing average, max, min value.

 

2. Principle

The device uses magnetic thickness measurement method, which non-destructively measures thickness of non-magnetic coating (such as: aluminum, chromium, copper, enamel, rubber, paint, etc.) on magnetic metal substrates (such as steel, iron, alloy and hard magnetic steel, etc.).

 

Magnetic Method (F-type probe)

When the probe contacts the cover layer, the probe and magnetic substrate forms a closed magnetic circuit; Due to the presence of non-magnetic coating, magnetic resistance changes. The thickness of the cover layer can be derived by measuring the change.

 

Eddy Current Method (NF-type probe)

When the probe contacts the cover layer, the probe and non-magnetic substrate forms Eddy Current and gives feedback to the coil inside the probe.

The thickness of the cover layer can be derived by measuring the feedback.


3. Technical Data

 

Model

WH81

WH82

Principle

Magnetic Method (F-type probe)

Magnetic Method (F-type probe) & Eddy Current Method (NF-type probe) 

Range

0-1250um

/

 

Accuracy error

zero calibration ± (1 + 3% H);

two-point calibration ± [(1% ~ 3% H)]  H + 1.5

/

Power

2 * AA battery

/

Unit

Um/mil

/

Temperature

0-40 ℃

/

humidity

≤85%

/

Minimum substrate

10 * 10mm

/

Minimum curvature

5mm convex; 5mm concave

/

Thinnest substrate

0.4mm

/

lWeight

99g

/

lSize

110mm * 65mm * 30mm

/

 

4. Item Checklist

 

Name

Quantity

Meter device

1

Standard films

5

Base substrate

1/2

5 dry cell

2

Packing box

1

User Manual

1

 


Because of the Express Company policy, not including the batteries

 