The XMS-Series of manual pull stations are a complete addressable and conventional pull station portfolio including single action, dual-action, 2-Stage, and metal versions. The addressable versions feature built-in Class X (Style 7) isolation capability for increased system survivability. All models feature a T-45 reset key to match the fire alarm panel enclosure. Addressable models also feature a tri-color status LED to indicate normal, alarm, and trouble status. All models utilize one address. The manual stations can be commissioned to operate in non-isolation (polarity insensitive) or isolation with Class X mode of operation.

Specifications Models XMS-S, XMS-D, XMS-DA, XMS-2S, and XMS-M are compatible with Siemens FACPs. The Model XMS-S is a single action pull station in a plastic housing that requires one action by the user to initiate the alarm. Models XMS-D, XMS-2S, and XMS-DA are dual-action pull stations in a plastic housing that require two actions by the user to initiate an alarm. The Model XMS-M is a single action pull station in a metal housing that requires one action by the user to initiate the alarm. These models are field installed addressable devices containing advanced control panel communication technology. 

The XMS-Series manual pull stations feature a "maintenance trouble" that places the fire alarm panel into a trouble condition if an XMS is accidentally left in an armed status when the cover is removed for maintenance work. This technology provides bi-directional communication with the connected control panel. To reset the stations, insert the Siemens T-45 key provided into the key lock and turn the key 10-15 degrees counterclockwise as the arrow shows. The cover will move upward to the normal position. Rotate the key clockwise and remove key from the lock. At Normal position the top of the Cover is flush with the top surface of the Base. Reset the Fire Alarm Control Panel to clear the alarm. The addressable XMS pull station variants are compatible with all current models of Desigo Fire Safety & Cerberus PRO commercial fire alarm control panels. These devices can be wired in either Isolation Mode or Polarity Insensitive Mode Wiring.

The XMS-S & XMS-M manual station front cover has a recess pocket to pull down and locks in position after the alarm is initiated. The XMS-D, XMS-DA & XMS-2S manual stations have an additional lever labeled “PUSH HERE THEN” to get access to the front cover pocket to initiate the alarm. 

1P S5321-F7-A1

Shipping

Once we receive full payment, your order will be shipped within 1-3 business days. Please note that there may be delays due to flight schedules, holidays, weather conditions, local postal services, or natural disasters. If your shipment is delayed, we appreciate your patience and encourage you to contact us for assistance. We will do our best to help resolve the issue.

Please be aware that import duties, taxes, and additional charges are not included in the item price or shipping fees. These charges are the buyer’s responsibility. Kindly check with your country’s customs office to determine any additional costs before making a purchase.

Returns

If you receive a defective item or the item does not function properly, please contact us for the return address. Returns are accepted within 30 days of receiving the item. The item must be returned in its original condition, and the buyer is responsible for return shipping costs. Once we receive the returned item, we will either issue a replacement based on available stock or provide a refund if a replacement is unavailable.

Feedback

Dear customers, we value your business and strive to offer excellent service. If you are satisfied with our products and service, we kindly ask that you rate the transaction with a "PERFECT 5 STARS" on eBay and leave positive feedback. Our system will automatically return the favor.

If you have any concerns or questions, please contact us directly before leaving neutral or negative feedback. We are committed to resolving any issues and offering the best possible service.

Disclaimer

We are not affiliated with any fire alarm manufacturers or dealers. We offer high-quality new and seller-refurbished fire alarm parts to help you maintain your existing fire systems. We buy, sell, and liquidate excess fire alarm parts. All trademarks, brand names, and logos mentioned are for identification purposes only and remain the property of their respective owners.

While FIRE-ALARM99 strives to provide accurate, complete, and up-to-date information on this site, we cannot guarantee its accuracy. No warranty of any kind?implied, expressed, or statutory, including but not limited to warranties of non-infringement, title, merchantability, fitness for a particular purpose, or freedom from computer viruses?is provided with respect to the contents of this site or its links to other resources.

Any reference to specific commercial products, processes, or services, or the use of any trade, firm, or corporate names is for public convenience and does not imply endorsement or recommendation by FIRE-ALARM99.

All fire alarm parts should be installed and tested by a certified fire alarm professional in accordance with local codes and NFPA standards.