Accuracy
1%
Connection
Male NPT
Type
Accessory
Options
BACnet/Modbus Communication
Housing Electrical Connection
PG Gland without Cable
Connection Size
1 in
Service: Compatible clean or dirty non coating, conductive liquids
Range: 0 to 20 ft/s (0 to 6 m/s). *
Wetted Materials:
Body shaft/fitting: 316 SS
Electrodes: 316 SS
Electrode cap: Polymer/Polystyrene
O-ring: Silicone
Accuracy: IEF-HX-X: ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at <2 ft/s (0.6 m/s); IEF-SX-X: ±1% FS
Temperature: Limits Ambient: -20 to 160°F (-29 to 71°C); Process: 15 to 250°F (121°C); Storage: -40 to 185°F (-40 to 85°C)
Process Connection: 1" NPT or BSPT with accessory full port ball valve options
Pressure Limits: 400 psi (27.6 bar) @ 100°F(37.8°C)
Pressure Drop:<0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe
Outputs:
(1) Analog: 4 to 20 mA, 0 to 5 V, 0 to 10 V or 2 to 10 V (display selectable)
(1) Pulse/Frequency: 0 to 15 V peak pulse, 0 to 500 Hz or scalable pulse output (display selectable)
(2) Alarm: (1) Empty pipe detection or minimum/maximum velocity, (display selectable)
(1) Reverse flow output indication
Power Requirements: 12 to 42.4 VDC, 0.25 A @ 24 VDC; 12 to 36 VAC
Electrical Connection: Removable terminal blocks, model selectable 1/2" female NPT conduit connection, PG 16 gland or PG 16 gland with (2) 10 ft (3 m) 9 conductor 22 AWG plenum rated cables, accessory cable lengths up to 200 ft (61 m) optional
Display (-LCD option) 2" (5.08 cm) x 2" (5.08 cm) graphic LCD with backlight
Conductivity:>20 microsiemens
Enclosure Material: Powder coated die cast aluminum
Enclosure Ratings:
NEMA 6P (IP68) (Non display models)
NEMA 4X (IP66) (-LCD option)
*For max flowrates >10 ft/s (3 m/s) order option -CC.:
Type
BACnet MS/TP or Modbus® RTU communication protocol (default disabled, display selectable)
Supported Baud Rates: 9600, 19200, 38400, 57600, 76800, or 115200 bps (display selectable)
Device Load: 1/8-unit load
Applicable Pipe Material: Most popular plastic and metal pipes, i.e. carbon steel, SS, copper, UPVC/PVDF, galvanized steel, mild steel, and brass. **
Applicable Pipe Size: IEF-HX-X: 4 to 10" (101 to 254 mm); IEF-SX-X: 4 to 36" (101 to 914 mm)
Diameter Length Requirements:>10 upstream, >5 downstream
Glycol: 0 to 100% display selectable
**Brass fittings and pipe are not to be used with NSF certified models.:
Approvals: BTL, CE, NSF/ANSI 61 and 372 pending
Product Features Continued: