Product Details

Parameters:
Measurement accuracy: 1% ±2 words
Measuring range: AC voltage: AC50.0-300.0V(or AC250.0-450.0V), the user when ordering according to the need to choose a suitable range)
Ac current: AC0-99.99A, current display resolution is 0.01A, more than 100A display 100.0A
Power frequency: 45.0Hz-65.0Hz
Power factor: 0.00-1.00PF
Active power: The measuring range is 0-3000W or 0-45,000W, the display resolution is 0.1W between 0-9999.9W, and the rest is 1W
Power: The measuring range is 0-99999kwh, 0-999.99kwh minimum display resolution is 0.01kwh 10000.00-9999.9kwh minimum display resolution is 0.1kwh,
10000.0-99999kwh Minimum resolution is 1kwh
Measurement speed: about 2 times per second
49 * 47 * 52 (mm)
Hole size: diameter Φ22mm
Save function/memory function: Automatic save function: in case of power failure, the meter will automatically save the current power value, and the meter will read the value after the next power on, and continue to accumulate.

Usage and wiring method:
1. Connect the cables according to the attached wiring diagram, and insert the two-wire plug accompanying with the secondary terminal of the current transformer into the secondary input terminal of the instrument. Pass the main circuit conductor of the current test through the middle round hole of the CT.
2. Connect the voltage measurement lead to the voltage input terminal of the meter. Then the voltage is measured. Start reading the measurement results.
3. The power reset button of the instrument is on the lower right side of the instrument. When the power reset is needed, use a round holder with a diameter of less than 2mm to gently press in the reset hole for 5 seconds, so that the accumulated value of electric energy can be multiplied to zero

Note:
250-450V meters are only suitable for pure AC 50 mains power supply, not for square wave, inverter output and modified sine wave circuit measurement, otherwise the meter will be damaged. Gauges with a 50-300V range are not affected

Package List:
Multifunctional measuring instrument *1
Transformer * 1
  • Payment must be received in 5 business days of auction closing.
  • Please leave note for your special request (e.g. Colors or Size) when you pay the order.
  • Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.

1. We only ship to the confirmed address provided by eBay. please make sure your ebay address is 100% matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
2. Orders will be processed instantly and dispatched within 1-3 business days except hoilday, so we do NOT accept any email/message note after you place orders.
3. All package need to wait 30 days,Please take care it.Less than 30 days,we can't take a refund.

    We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.

Datacaciques