Solar Water Heater Controller SEA-SC-1910(for pressurized solar water heater) 

SEA Solar hot water intelligent controller is the product that applies the single chip microcomputer (SMC) 
technology and it has been made through many living imitation experiments to optimize the controlling 
software.  The controller brings functions that ensure the solar system works efficiently, to achieve 
automatic controlling of water level, displaying of water temperature and automatic loading of water etc. 
 

Features of SEA Intelligent Controllers for Solar Water Heater:
  •   Complete control functions
  •   High and stable quality
  •   Reliable performance with strong post-sale customer service
  •   Reasonable pricing

Basic System Functions:
  •   Clock  display
  •   Temperature differential function “on/off”
  •   Maximum  tank  temperature setup/control
  •   Frost  protection
  •   Temperature difference controlling hot water circulation pump
  •   Time controlled hot water circulation pump
  •   Temperature controlled auxiliary heating during three time section
  •   Protection functions  (a. Memory protection,  b. anti-bacteria protection)
  •   Temperature display in / between“°C /  °F”

Increased System Main Functions (with different controller model SEA-SC20-10):
  •   Clock / week display
  •   8 systems to choose from:
  • System 1: one collector array, one storage tank, one pump
  • System 2: one collector array, two storage tanks, two pumps
  • System 3: one collector array, two storage tanks, one pump – one electromagnetic valve
  • System 4: two collector arrays, one storage tank, two pumps
  • System 5: two collector arrays, one storage tank, one pump – one electromagnetic valve
  • System 6: two collector arrays (east and west, controlled by electromagnetic valve), two 
    storage tanks, one pump – two electromagnetic valves
  • System 7: two collector arrays (east and west, controlled by electromagnetic valve), two 
    storage tanks, two pumps – one electromagnetic valve
  • System 8: two collector arrays (east and west, controlled by pumps), two storage tanks, 
    two pumps – one electromagnetic valve
  •    Temperature differential function “on/off”
  •    Maximum tank temperature setup/control
  •    Collector emergency shut-off
  •    Limited operation of collector at low temperature
  •    Frost protection
  •    Temperature difference controlling hot water circulation pump
  •    Time controlled hot water circulation pump
  •    Temperature controlled auxiliary heating during three time section
  •    Holiday function
  •    Auto function
  •    Auxiliary heating function / (a. Temperature difference controlling (ΔT2),b. Heating return  
    increase, c. High temperature by-pass)
  •    Protection functions (a. Memory protection, b. anti-bacteria protection, c. anti-dry heating 
    protection)
  •   Temperature display in / between“°C /  °F”