Agilent Varian Cary 5000 UV-Vis-NIR DRA-2500 Reflectance System (Needs Repair)

Research-grade double-beam UV-Vis-NIR spectrophotometer and optical reflectance measurement system configured for transmission, diffuse reflectance, fixed-angle specular reflectance, absolute specular reflectance, and polarized optical measurements.

This system includes an installed Internal DRA-2500 along with a substantial collection of specialized reflectance and polarization accessories.

Two Harrick specular-reflection assemblies are included as complete mounted configurations: an ERA-45G 45° accessory and an ERA-22G 22.5° accessory, each installed on its respective floor-mounted fixed-angle assembly.

The package also includes a VW Absolute Specular Reflectance Accessory, Harrick polarizer and depolarizer, RBA holder, chamber extension hardware, spare visible-source lamp, manuals, and the Windows XP control computer associated with the instrument.

!!! IMPORTANT DISCLAIMER !!!

The instrument lamps are operating; however, the front-channel detector is currently not detecting light.

A professional service estimate of approximately $7,000 was obtained for repair/service associated with this condition. Repair has not been completed.

Buyer should assume that professional service, repair, alignment, calibration, or additional troubleshooting will be required before the system can be returned to full analytical operation.

Specifications 

Included Accessories

Dimensions 

       40.0" x 30.0" x 20.0" (300 lbs)

Comes from a professional working environment. Acquired from an active laboratory in partial working order. In good cosmetic condition (See pictures). Pre-owned research laboratory system. The Cary 5000 powers and the instrument light sources have been verified operational. The system currently has a known functional issue: the front-channel detector is not detecting light. A professional service quote of approximately $7,000 was previously obtained to address the detector-related issue. The repair has not been performed. Because of this known detector fault, the system is being sold AS-IS for repair/service. It should not be considered fully operational or calibrated in its present condition. No representation is made regarding current wavelength accuracy, photometric accuracy, detector performance, or measurement calibration beyond the specific testing described above. See pictures. See description for full specs. 

Shipping

  • Orders ship within 1 business day of payment, subject to freight scheduling.
  • We do not ship to Alaska, Hawaii, territories, or APO/FPO mailboxes unless prior arrangements are made.
  • Any orders shipped via shipping or freight forwarder are final sale with no returns.

Freight

  • All freight damage must be noted on the Bill of Lading (BOL) at the time of delivery.
  • Take clear photos of:
    • The damaged item
    • Packaging
    • The BOL damage notation
  • Retain all original packaging until the claim is resolved.
  • Failure to follow these steps may result in denial of any refund related to shipping damage.
  • International buyers are fully responsible for:
    • Customs clearance
    • Duties and taxes
    • Brokerage fees
  • Buyer must arrange for their own customs broker if required. Seller does not provide customs clearance services.
  • All shipments are FOB origin, title and risk transfer to buyer at shipping point.

Returns

  • Anacapa Equipment Brokers, Inc. is committed to excellent customer service.
  • Items are sold as-is with a 30-day Right of Return, unless otherwise stated.
  • Only items shown in the listing photos are included.
  • Buyer may return equipment for any reason within 30 days of receipt, provided it is returned in the same condition as shipped.
  • No returns or refunds will be accepted if the buyer uses a shipping or freight forwarder for international shipment.

Store Policies

  • All equipment is sold as-is with no warranty of merchantability or fitness for a particular purpose.
  • Buyer assumes all risk regarding the quality, performance, suitability, and safety of the equipment.
  • Equipment should only be installed and operated by qualified personnel.
  • Seller is not liable for any damages, injuries, or losses, incidental or consequential, related to the use of purchased equipment.
  • Buyer agrees to defend, indemnify, and hold harmless Anacapa Equipment Brokers, Inc., its officers, employees, and agents from all claims, damages, or expenses, including legal fees, arising out of the purchase, ownership, or use of equipment.