High-Precision Inductance and Capacitance Meter Digital A6243L/A6013L Capacitance Meter with Backlit Digital Display Multimeter 20MF20H


A6013L

Model: A6013L

200 pF Range: Resolution 0.1 pF, Accuracy ±(0.5% + 5d), Test Frequency 820 Hz

2000 pF Range: Resolution 1 pF, Accuracy ±(0.5% + 5d), Test Frequency 820 Hz

20 nF range: Resolution 10 pF, accuracy ±(0.5% + 5d), test frequency 820 Hz

200 nF range: Resolution 100 pF, accuracy ±(0.5% + 5d), test frequency 820 Hz

2 μF range: Resolution 1 nF, accuracy ±(0.5% + 5d), test frequency 82 Hz

20 μF range: Resolution 10 nF, accuracy ±(0.5% + 5d), test frequency 82 Hz

200 μF range: Resolution 100 nF, accuracy ±(2.0% + 10d), test frequency 8.2 Hz

2000 μF range: Resolution 1 μF, accuracy ±(2.0% + 10d), test frequency 8.2 Hz

20 mF range: Resolution 10 μF, accuracy ±(4.0% + 10d), test frequency 8.2 Hz

Power Supply: 9V (NEDA1604/6F22) × 1

Maximum Display: 1999


General Overview (A6013L/A6243L)

Product Type: Handheld Digital Multimeter

Product Features: Stable performance, high reliability, compact design, ultra-miniature and portable, wide measurement range, LED backlit display, clear readings


A6243L Inductance Parameters

Model: A6243L

2 mH inductance range: Resolution 1 μH, test frequency 1 kHz, test current 60 μA, basic accuracy ±(2.0% + 5)

20 mH Inductance Range: Resolution 1 μH, Test Frequency 1 kHz, Test Current 60 μA, Basic Accuracy ±(2.0% + 5)

200 mH Inductance Range: Resolution 100 μH, Test Frequency 1 kHz, Test Current 60 μA, Basic Accuracy ±(2.0% + 5)

2 H inductance range: Resolution 1 mH, test frequency 1 kHz, test current 6 μA, basic accuracy ±(3.0% + 5)

20 H inductance range: Resolution 10 mH, test frequency 100 Hz, test current 600 nA, basic accuracy ±(5.0% + 15)


# A6243L Capacitance Parameters

2 nF capacitance range: Resolution 1 pF, test frequency 200 Hz, applied voltage 75 mV, basic accuracy ±(1.0% + 5)

20 nF capacitance range: Resolution 10 pF, test frequency 200 Hz, applied voltage 75 mV, basic accuracy ±(1.0% + 5)

200 nF capacitance range: Resolution 100 pF, test frequency 200 Hz, current 75 mV, basic accuracy ±(1.0% + 5)

2 μF capacitance range: Resolution 1 nF, test frequency 200 Hz, current 75 mV, basic accuracy ±(2.0% + 5)

20 μF capacitance range: Resolution 10 nF, test frequency 200 Hz, test current 75 mV, basic accuracy ±(2.0% + 5)

200 μF capacitance range: Resolution 100 nF, test frequency 20 Hz, test current 75 mV, basic accuracy ±(2.0% + 5)