Description
TESTED - This listing is for an ILP Type 10014 toroidal transformer, new in its original box and complete with the factory mounting hardware. The unit has never been installed.
Testing
The transformer was tested with a Variac from 0 to 120 VAC. All windings were verified for continuity, isolation, and correct voltage output.
Primary
- Brown to Brown
- Measured DCR: 35.5 ohms
- Verified for 120 VAC operation
Secondary 1
- Blue to Grey
- Measured DCR: 2.1 ohms
- Output at 120 VAC input: 23.1 VAC
Secondary 2
- Red to Yellow
- Measured DCR: 2.1 ohms
- Output at 120 VAC input: 23.1 VAC
Notes
- Both secondaries are identical 23 VAC windings
- Suitable for independent, series (≈46 VAC), or parallel (23 VAC at increased current) configurations
- No cross‑winding continuity detected
- Transformer runs cool and stable during testing