DSE705 DSE-705 NEW For Auto Transfer Switch ATS Genset/Generator Controller

Details

Part No.: DSE705
Package includes: 1 pc Generator Controller
The DSE 705 is an Auto Transfer Switch Control Module designed to monitor the mains (utility) supply. When the mains (utility) power fails, the module sends a start request to the generator control unit. When the generator is up and running, the module transfers the load across. When the mains (utility) returns the module transfers the load back and removes the start command. The generator should then begin it's shutdown procedure. The module can be configured so that they follow the users pre-set start and stop sequences.

Features:
Main Features:
·Automatic mains (utility) supply monitoring 
·Load changeover control 
·Manual start 
·Protected solid state (PSS) outputs 
·Front panel mounting 
·Front panel programming 
·LED indicators 
·Configurable timers 
·Configurable outputs 
·Single/three phase mains sensing
Benefits:
·Transfer’s between mains and generator power 
·On-site module configuration to match user requirements
Operation:
The module is operated by the three push-buttons on the front: 
Manual Off Load –This is used to manually start and run the engine off load. Should the mains (utility) supply fail, then the load is transferred to the generator automatically. 
Manual On Load - 
This mode is used to manually start and run the engine on load. 
Auto Mode –This puts the module into automatic mode, where it will await a mains failure. Upon detection 
it will send a start request to the generator control unit.
DC Supply:8 Volts to 35 Volts DC Continuous.
Cranking Dropouts:Able to survive 0 Volts for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 Volts.This is achieved without the need for internal batteries.
Max. Current:Operating 50mA
Standby: 10mA
Alternator Input Range:75 Volts (ph-N) to 277 Volts (ph-N) AC (+20%)
Mains Input Voltage:15~277 Volts (ph-N) AC (+20%)
Alternator Input Frequency: 50~ 60 Hz at rated engine speed
(Minimum:75V AC Ph-N)
Generator available: 45Hz
Generator failed :20Hz
Mains Frequency:50~60 Hz
Start Output:1.2 Amp DC at supply voltage.
Fuel Output: 1.2 Amp DC at supply voltage.
Auxiliary Outputs:1.2 Amp DC at supply voltage.
Charge Fail: 12 Volts = 8 Volts CF 24 Volts = 16 Volts CF
Dimensions: 125mm x 165mm x 28 mm
Operating Temperature Range:-30°C to + 70°C
Applicable Standards: Compliant with BS EN 60950 Low Voltage Directive
Compliant with BS EN 50081-2:1992 EMC Directive
Compliant with BS EN 61000-6-4:2000 EMC Directive


International Buyers -  Please Note: 
Import duties, taxes and charges are not included in the item price or shipping charges. 
These charges are the buyer's responsibility.

Shipment

If you need to receive the goods urgently, please contact us to consult the delivery time before purchasing.

 Delivery  Time

Expedited Shipping (FedEx/DHL) : USA 3-6 business days, Other country 3-9 business days;

Economy Shipping: USA 7-15 business days, Other country 10-30 business days.

Shipping Address

We are unable to ship to PO Boxes or APO/FPO addresses, please leave physical address on ebay. If you want to change the address, just feel free to contact us when purchasing.

 Handing Time

Items will be shipped within 1 to 3 business days after payment confirmation.

 Note

 If you don't receive items over 30 business days, please contact us.

Return & Feedback

We offer 30 days return policy. If you are not satisfied with the item, you can return it, except for any installed parts.

Please send item back in original package (new and un-used, accessories included). 

Once warehouse receive the item in new condition, we will send refund.

If your package is lost in transit to us, we are not responsible for any loss or damages and cannot refund you.

When you satisfied with our product and services, please leave us positive feedback.

Please DO NOT leave negative feedback without communication with us, thank you!