Specifications:


Main material: ABS


Supply Voltage: AC 100V-240V 50/60Hz


Measuring possibilities: rate deviation, amplitude, be-at error of mechanical watches and diagram recording of the be-at noise.


Rate deviation measurement:


Measuring ranges: ±999s/d or ±99.9s/d


Resolution: 1.0s/d or 0.1s/d


Amplitude measurement:


Measuring ranges: 100°~360°


Resolution: 1°


Measuring of the be-at error:


Measuring ranges: 0.0~9.9 ms


Resolution: 0.1 milliseconds


Lift angle:


Measuring ranges: 30°~70°


Default value: 52°


Measure positions: 1-6 positions


Line length: 480 points


Measuring times periods: 2/4/6/8/12/20/30/60 seconds


Language: Chinese, English, Japanese


Display: color LCD graphic monitor, 480*272 pixels


Working environment: 10℃~40℃


Relative humidity: 0~80% RH


Item size: 185 * 120 * 40mm / 7.3 * 4.7 * 1.6in


Item weight: 337g / 11.9ounce


Package size: 230 * 210 * 195mm / 9.1 * 8.3 * 1.6in


Package weight: 1379g / 3.0lb




Automatic:


The following beat numbers are selected by automatic selection mode:12000、14400、18000、19800、21600、25200、28800、36000、43200。


(If the tested beat is not in automatically selection, the instrument will display the closest beat number, but the test result is not correct. At this time, use the manual mode to select the relative beat.)




Manual selection:


It can selected out the beat number that Automatic select can not identify and rare beat number.


The following beat are selected by Manual selection mode:


3600、6000、7200、7380、7440、7800、9000、9100、10800、11880、12000、12342、12480、12600、13320、13440、13500、14000、14040、14160、14200、14280、14400、14520、14580、14760、14850、15000、15360、15600、16200、16320、16800、17196、17258、17280、17786、17897、18000、18049、18514、19332、19440、19800、20160、20222、20944、21000、21031、21306、21600、25200、28800、32400、36000、43200.




Feature:


The frequency diagram of the watch can be displayed on the LCD screen.


According to different watches, the instrument will automatically adjust the optimal signal level during the test.


The instrument will automatically calculate the rate deviation, amplitude, be-at error, and display them by the data in real time; select "±99.9s/d" at item rate ranges for result display, which can make the accuracy of rate deviation up to 0.1s/d.


For the conventional be-at, the instrument can automatically respond; for the special be-at, can manually select.


The sampling period can be selected by 2 seconds, 4 seconds, 6 seconds, 8 seconds, 12 seconds, 20 seconds, 30 seconds, 60 seconds, and the average value of corresponding period will be regarded as the precise value of the watch.


Six kinds of testing positions can be adjusted, and the simulation sound can be played in the speaker or mute.




Package Included : 


1 * Timegrapher


1 * Timegrapher Sensor


1 * Adapter (US/UK/EU/AU)


1 * User Manual