👍 Display Mode: Liquid crystal display

👍 Measurement Method: Oscillometric method

👍 Operating Voltage: DC 6V (4 AAA batteries)
     *Due to shipping restrictions, this product does not include AAA batteries.

👍 Measuring Range:  
- Blood pressure: 0 mmHg~280 mmHg (0 KPa~37.3 KPa)  
- Pulse rate: 40-199 beats/min

👍 Allowable Error:  
- Blood pressure: ±3 mmHg (±0.4 KPa)  
- Pulse rate: ±5%

👍 Inflation Method: Automatic inflation

👍 Measurement Result Display: High pressure value / Low pressure value / Pulse rate

👍 Number of Memory Groups: 99 memory groups for each of the two persons

👍 Low Voltage Reminder: The screen displays the "Battery" symbol to indicate low voltage

👍 Indication of Heart Rate Irregularity: The display shows the "Heart" symbol blinking to indicate heart rate irregularity

👍 Automatic Shutdown Function* No operation for 1 minute ± 15s results in automatic shutdown

👍 Adjustable Large Cuff: 8.66''-16.53''

Product Information:

Product Name: Arm-type Electronic Blood Pressure Monitor  

Display: LCD High Definition Display  

Measurement Method: Oscillometric Method  

Memory Capacity: 99 sets of memory values for each of two users  

Measurement Range: 

- Blood Pressure: 0 mmHg - 280 mmHg  

- Pulse: 40 - 199 beats per minute  

Allowable Deviation:  

- Temperature: +5°C to +40°C  

- Humidity: <80% RH  

Transportation and Storage Environment:  

- Temperature: -20°C to +55°C  

- Humidity: <93% RH  

Power Supply: DC 6V / DC 3.7V  

Service Life: 5 years

Package Includes:
1 x Blood Pressure Monitor
1 x Large Cuff 22-42cm
1 x USB Cable
1 x User Manual

Return

We accept return within 30 days after you order.

If you have any problem about the product, feel free to contact us.


Questions & Answer

1.The measure reading is not accurate?

For get more accurate result,please follow these tips:

  • Sit still for five minutes before measurement.
  • Be seated in a chair with back support.
  • Put your arms out in front of the table with your palms up and your fingers soft.
  • Place a towel between the elbow and the sphygmomanometer to keep the arm stable.
  • Keep the sphygmomanometer at the same height as the heart.
  • Attention: Repeated measurement will lead to congestion of the wrist and affect the measurement results. Improvement method: raise the left hand and shake the fist several times, or take off the cuff and rest for at least 4-5 minutes before measurement.
  • Average value for the last three records.

2.What does the error message on the screen indicate and how to deal with it?

  • When error 1 is displayed, the sensor signal is abnormal, indicating that the component is damaged and cannot be measured, please tell us for processing.
  • When error 2 is displayed, please tighten the cuff and measure again.
  • When error 3 is displayed, please keep your arm or body still and measure again.
  • When error 4 is displayed, it means the cuff is too loose or air leakage, please tighten the cuff and measure again.
  • When error 5 is displayed, the cuff is too tight or the air circuit is blocked, adjust the cuff and measure again.
  • When error 6 is displayed, it means serious pressure interference during measurement, please hold your arm or body still and measure again.
  • When error 7 is displayed, it means the pressure value exceeds 295mmHg (39.33Kpa), please remeasure.

3.How to delete the old records?

  • When viewing the memory, press and hold the [MEM] key while holding down the [START / STOP] key for 2 seconds. When the screen displays all "-", the memory will be deleted.
  • Attention: Memory deletion is to delete all measurement data under one user at a time.