Thermocore 36000 BTU AC-Heat 22 SEER
Thermospace Mini Split

Thermospace Contact

36000 BTU Quad Zone Energy Star Mini Split AC
22 SEER Efficiency w/ Heat Pump Technology
With a 36000 BTU total Cool / Heat Capacity, the Thermocore T425D-H248 6+6+12+12 Energy Star mini split AC can cool or heat two separate 6000 BTU, 12000 BTU, and 12000 BTU zones for a total coverage area of 1700 ft² [250 + 250 + 600 + 600 ft²]]. Most Energy Efficient Quad-Zone series on the market! - 22 SEER coupled with Inverter technology provides the benefits of low operation temps as well as maximum energy efficiency. 4 x 15ft Install kits included. 1 Year Part - 5 year compressor warranty.
36000 BTU Tri Zone Mini Split

Mini Split AC Heat Pump Inverter SystemTop

Indoor Units Remote Controls Outdoor Unit Installation Kit

Technical Data:
System Includes:
  • 36000 BTU INVERTER Cooling Capacity (6+6+12+12)
  • 36000 BTU INVERTER Heating Capacity (6+6+12+12)
  • 22 SEER - 11 HSPF - AHRI / ENERGY STAR Eligible*
  • Pre-Charged with ECO-Friendly R410A
  • 1 Year Parts - 5 Year Compressor Warranty View Details >

  • Indoor Unit - Air Handler.
  • Outdoor Unit - Condenser of 48,000 BTUs
  • Digital Multi-function LCD Remote Control.
  • Installation Kit with 15' x 4 of lineset. >>>
  • Product and Installation Manual. >>>
** Rated Capacity of Condenser will be less than actual delivered capacity in above configuration. Rated Capacity is not the same as Maximum Capacity.
Click here for Capacity Calculation Table. SEER is based on using with heads packaged with system. Energy label will state 17.8-22 SEER **
Mini Split AC FeaturesTop

Inverter Split
Top Line Features:
  • 22 SEER - 11 HSPF - ENERGY STAR Energy Star
  • Most Energy Efficient 4-Zone Series on Market
  • Dry-Mode removes moisture w/o affecting temp
  • Cross Flow Technology reduces noise output
  • Compatible with over 5 Filtration medias
  • Freon Leak Detection > Notification system
  • Low Ambient Temperature Operation (-13° F)
  • Two-direction Air vane Evenly Distributes Air
  • Restart IC: Settings restored Following Outage
  • Follow-Me Function tracks Remote Location

feature

The particle filter or “pre-filter” removes dust and other air-borne pathogens before pushing the air through additional filtration medias and the refrigeration coil array. This filter is washable and comes factory installed with every ductless air conditioner system.
The open channel construction of the 3M High Air Flow (HAF) filter offers low initial airflow resistance, while its unique microstructure and electrostatic charge provides effective particle capture and retention. This translates into fewer filter change outs and reduced coil cleaning. CLICK TO PURCHASE >>>
The Vitamin C Filtration media releases Vitamin C into the air which softens skin and reduces stress among other therapeutic benefits. A good choice for those wanting to add some invigoration to their indoor air environment. Filter lasts over 2 years. CLICK TO PURCHASE >>>
The anti-microbial effect of silver ionic technology kills allergy causing bacteria by destroying the inner configuration elements of the cell body. The nano-silver attached to the filter screen constantly releases silver ions which directly eliminates and prohibits bacteria from replicating. CLICK TO PURCHASE >>>
Eliminates odors such as ammonia and deactivates harmful chemicals has such as formaldehyde. By forming positive positions on the filter surface, Electrostatic Fiber traps small dust particles, smoke and pet dander to prevent allergic reactions and neutralize odor in the air. CLICK TO PURCHASE >>>

Mini Split AC SpecsTop

6000 BTU Indoor Unit specs CLICK FOR FULL SPEC SHEET

Model Number T5HH27S-H206-E
Capacity 6000 BTU
Air Flow (Hi/M/Lo) 317.65 / 217.65 / 167.65 cfm
Power Supply 208/230,1,60 (V, PH, HZ)
Input Power 50W
Noise Output (Hi/M/Lo) 36/32/23 dBA
Liquid / Gas 1/4" x 3/8"
Weight 22.71 / 28.88 lbs
Dimensions (W x D x H) 33.66 x 9.09 x 11.69 inches


12000 BTU Indoor Unit specs CLICK FOR FULL SPEC SHEET

Model Number T3-OS212-E
Capacity 12000 BTU
Air Flow (Hi/M/Lo) 520/360/250 cfm
Power Supply 230 V / 60 Hz / 1Ph
Noise Output (Hi/M/Lo) 36.5/30/25 dBA
Liquid / Gas 1/4" x 1/2"
Weight 18.1 lbs
Dimensions (W x D x H) 31.6" × 7.45" × 11.7" in.




Model Number T425D-H248
Compressor Brand TOSHIBA / GMCC
Maximum AH Capacity 48,000 BTU
Air Flow 2355 CFM
Power Supply 230 V / 60 Hz / 1Ph
Input Power 2600W - 3800W
Max Fuse 45A
SEER 22.5
EER 12.50
HSPF4 11
Sound Level 65 dBA
Operating Temp Range -13 - 122 F (cool and heat)
Refrigerant R410A / 105oz Charge
Liquid / Gas 1/4" x 3/8" (4)
Max Lineset Length (1 zone) 98 ft
Max Lineset Length (all zones) 197 ft
Weight 156.3 lbs
Dimensions (W x D x H) 37.25 × 16.14 × 31.89 inches
R-410A Refrigerant Energy Star Toshiba Compressor Cooling & Heating 19 SEER
Mini Split Installation KitTop

Install Kit Contents:
  • 15 Feet Flared Copper Tubing x 4
  • 15 Feet Pipe Insulation x 4
  • Drain Pipe (outdoor)
  • Outdoor Condenser Rubber pads
  • Wall Bracket for Indoor Unit x 4
  • Brass Adaptors for Alternate lineset sizes
  • Installation and User Manuals

Includes Install Kit Install Kit
*** Extend 15 foot copper lineset to 25-30-40-50-65 feet. Just $4.50 / additional foot*** contact us for details >
Does not Include 16/4 Electrical Wire Harness - Click here to purchase

Install Kit back to the top


Inverter TechnologyTop
DC Inverter Mini Split AC Heat Pump
WHAT IS DC INVERTER?

DC Inverter Air Conditioners are the ultimate cooling technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.

Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained.



DC Inverter Energy Efficient Heating & Cooling Mini Splits


Inverter Mini Split Air Conditioner Saves Money

Inverter Mini Split Air Conditioners Are Energy Efficient & Save Money


Ductless Split InstallationTop
BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with R410A Freon however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning of a split AC. *Although installation may seem easy to some, certain tools and experience is necessary to complete setup of a mini split* Click for Installation Tip. It is highly advised a certified HVAC technician complete installation to be eligible for warranty. See warranty details below >
Ductless Split Air Conditioner Installer

Installation Diagram For Mini Split Air Conditioning Units

following_install
Mini Split AC After Installation
Mini Split Air Conditioner After Installation


WarrantyTop

*5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and a brand new exchange will be shipped out. 1 YEAR PARTS WARRANTY CAN BE EXTENDED TO 2 YEARS FOR AN ADDITIONAL $72.00

Mini Split ShippingTop
US SHIPS TO TO BOTH UNITED STATES AND CANADIAN LOCATIONS! Canadian

Our Thermocore systems ship via RL Carriers or similar LTL freight service out of Warren, Michigan and are palletized onto a single skid. Transit time is usually between 4 to 6 business days from payment receipt depending on where you are geographically located. Please provide a contact phone# upon checkout (to be used for delivery purposes only). SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Failure to provide valid contact# will delay order. System comes with Free shipping - this includes delivery to any location within the Continental United States. We will ship to Canadian locations but we need to quote separately - please contact our offices. Additional freight for Canadian registries is usually around $150. (import and duties may apply).
RL Carriers


Ductless Mini Split Air Conditioner AccessoriesTop
Condenser Ground Stand

Stand

- Provides Flat even surface
- Avoids debris obstruction

Price: $73.00
Click for more Info

Lineset Extension (1/4 x 3/8)

Lineset

- Extend included 16 ft copper lineset to 25ft - 30ft - 40ft - 50ft
Price: $38.00 > $134.00
Click for more Info

Condenser Bracket

Bracket

- Mount your condenser at any height on an outdoor sidewall
Price: $78.00
Click for more Info

Micro-Pump II

Lineset

- Required when mounting air handler on Interior wall
Price: $182.00
Click for more Info


Electrical Wire Harness

Wire

- 16/4 Electrical Wire Harness
- For Extending Evap. Length

Price: $1.85 / ft
Click for more Info

Additional Remote Controls

Remotes

- Spare remote controls for the T1 Series Ductless System
Price: $42.00
Click for more Info

Filter Medias

Filters

- Inserts into Filter Screen Slot
- Choice of 4 Filtration Medias

Price: $10.00 - $14.00
Click for more Info

Wired Thermostat

Wired Thermostat

- Permanently Hard Mounts
- Controls Settings w/ Remote

Price: $78.00
Click for more Info

Available Accessories back to the top

Options


Swap 1 Mount for Cassette: (+) $150
Swap 2 Mount for Cassette: (+) $300
Swap 3 Mount for Cassette: (+) $450
Swap 4 Mount for Cassette: (+) $600
Swap 5 Mount for Cassette: (+) $750

* 9k heads do not come in cassette option - need to upgrade to 12k


Swap 1 Mount for Susp. Ceiling: (+) $160
Swap 2 Mount for Susp. Ceiling: (+) $320
Swap 3 Mount for Susp. Ceiling: (+) $480
Swap 4 Mount for Susp. Ceiling: (+) $640
Swap 5 Mount for Susp. Ceiling: (+) $800
This unit

*If alternate air handler types are preferred, contact us and request invoice with preferred options. Availability fluctuates.
Customize your system to meet your requirements - see below table for available output options:

Tri-Zone Setup
9k + 18k + 18k 9k + 18k + 24k
12k + 12k + 18k 12k + 18k + 18k
9k + 9k + 24k 12k + 12k + 24k
12k + 18k + 24k 12k + 24k + 24k
18k + 18k + 18k 18k + 18k + 24k
Quad-Zone Setup
9k + 9k + 12k + 12k 12k + 12k + 12k + 12k
9k + 12k + 12k + 18k 12k + 12k + 12k + 12k
12k + 12k + 12k + 18k 9k + 9k + 9k + 24k
9k + 12k + 18k + 18k 9k + 9k + 18k + 18k
9k + 18k + 18k + 18k 9k + 9k + 18k + 24k
12k + 12k + 18k + 18k 12k + 12k + 12k + 24k
Quad-Zone Setup
9k + 9k + 9k + 9k + [9/12/18/24]
9k + 9k + 9k + 12k + [12/18]
9k + 9k + 9k + 18k + 18k
9k + 9k + 12k + 12k + [12/18]
9k + 12k + 12k + 12k + 12k
12k + 12k + 12k + 12k + 12k

This system available in multiple air handler (zone) capacity combinations to meet the requirements of any application. Air handlers are available in 9k, 12k, 18k and 24k outputs. Be advised, for arrangements where combined output of all heads exceeds rated capacity of condenser (54000 BTU's) - the total output will not exceed 54000's when all air handlers are running at full capacity simultaneously. However, overated zones will draw required capacity from other zones either running at lower modes or areas that have reached thermostat settings to obtain rated output. For example, with a 12k-12k-12k-12k+12k configuration, the total output will be along the lines of 11k-11k-11k-11k+11k when all zones are running on high/full settings at the same time. However, once a zone obtains set temperature and/or operates at a lower setting, the capacity will bleed off into zone that needs the extra push to obtain the 12k-12k-12k-12k-12k yield. See Combination Calculation Table