Compact Low Profile Load Cell (SGSENSE)

Compact Low Profile Load Cell 5000N Capacity Amplified Voltage Output W CAN bus


Product Description: Compact Low-Profile load cells are fully stainless steel hermetically sealed load cells with a multi-beam internal structure and fully integrated electronics to provide high-level analog or digital outputs. This type of load cell is easy to use for measuring tension or compression loads from 200N (50lb) to 5kN (1000lbf) and is capable of rejecting side forces that would otherwise affect accuracy. This type also offers the user the ability to set the gain and offset (span and zero) electronically to provide maximum flexibility for the user application.

For detail specification, please visit: Compact Low Profile Load Cell (SGCLP) - SGSENSE (sgsensetech.com)

Specification

Parameter Range Notes
Rated load 200, 500, 1000, 2000 & 5000N
50, 100, 200, 500 & 1000lbf
Proof load 150% of rated load No effect on calibration
Ultimate load 200% of rated load No structural failure (deformation only)
Deflection <0.05 mm Depends on rated load
Natural frequency >1000 Hz Depends on rated load
Output at rated load (RO) 1-9 V or 4-20mA or CAN or RS485 or mV/V Select when ordering
Non-linearity <= 0.1% RO
Hysteresis <= 0.1% RO
Repeatability <= 0.03% RO
Creep over 20 minutes <= 0.03% RO
Output (span) tolerance factory setting ±0.1% range ±50% RO Adjustable via electronic interface. See user manual for details
Offset (zero balance) factory setting ±1.0% range ±50% RO Adjustable via electronic interface. See user manual for details
Output (span) temp coefficient ±0.005% load / °C
Offset (zero) temp coefficient ±0.005% RO / °C
Compensated temp range -10°C to +50°C
Operating temp range -40°C to +85°C
Power supply 12 to 24 VDC <40mA
Insulation resistance >=5 Gohm @ 50 VDC
Connector Analog O/P: 8-pin M12 male hermetic
Digital O/P: 5-pin M12 male hermetic
ESD safe EMC compliant with EN61326-2-3:2006 CE marked
Protection class IP68 Fully stainless-steel construction laser welded
Weight 750 g
Bridge resistance 700 Ohms Nom.

Dimensions

Dimensions – mm [inch]


Capacity (N) Centre thread size (through) Outer bolt size
200, 500 M8 x 1.25 M6 Socket Head Screw
1000, 2000, 5000 M12 x 1.75 M6 Socket Head Screw
Capacity (lbf) Centre thread size (through) Outer bolt size
50, 100, 200, 500, 1000 3/8-24 UNF-2B ¼” Socket Head Screw

Wiring Codes

Pin Voltage Output Current Output CAN RS485 mV/V
1 Supply (+) Supply (+) Shield Supply (+) Supply (+)
2 Supply (-) TEDS GND Supply (-) TEDS GND Supply (+) RS485_A Supply (-)
3 Signal (+) Current loop (+) Ground Ground Signal (+)
4 Signal (-) Current loop (-) CAN_H RS485_B Signal (-)
5 TEDS DATA/ Shunt calibration (Optional) TEDS DATA/ Shunt calibration (Optional) CAN_L Shield N/A
6 Calibration interface A Calibration interface A N/A N/A N/A
7 Calibration interface B Calibration interface B N/A N/A N/A
8 Calibration interface C Calibration interface C N/A N/A N/A
9

Order Details

Model (Capacity in N)

Model Capacity (N) Description
1010-10 200 1 mV/V Output. With M12H connector (hermetic)
1020-10 500 1 mV/V Output. With M12H connector (hermetic)
1030-10 1000 1 mV/V Output. With M12H connector (hermetic)
1040-10 2000 1 mV/V Output. With M12H connector (hermetic)
1050-10 5000 1 mV/V Output. With M12H connector (hermetic)
1010-20 200 Amplified Output (4-20mA). With M12H connector.
1020-20 500 Amplified Output (4-20mA). With M12H connector.
1030-20 1000 Amplified Output (4-20mA). With M12H connector.
1040-20 2000 Amplified Output (4-20mA). With M12H connector.
1050-20 5000 Amplified Output (4-20mA). With M12H connector.
1010-30 200 Amplified Output (1-9V). With M12H connector
1020-30 500 Amplified Output (1-9V). With M12H connector
1030-30 1000 Amplified Output (1-9V). With M12H connector
1040-30 2000 Amplified Output (1-9V). With M12H connector
1050-30 5000 Amplified Output (1-9V). With M12H connector
1010-40 200 Amplified Output (CAN/RS485). With M12H connector
1020-40 500 Amplified Output (CAN/RS485). With M12H connector
1030-40 1000 Amplified Output (CAN/RS485). With M12H connector
1040-40 2000 Amplified Output (CAN/RS485). With M12H connector
1050-40 5000 Amplified Output (CAN/RS485). With M12H connector

Model (Capacity in lbf)

Model Capacity (lbf) Description
1110-10 50 1 mV/V Output. With M12H connector (hermetic)
1120-10 100 1 mV/V Output. With M12H connector (hermetic)
1130-10 200 1 mV/V Output. With M12H connector (hermetic)
1140-10 500 1 mV/V Output. With M12H connector (hermetic)
1150-10 1000 1 mV/V Output. With M12H connector (hermetic)
1110-20 50 Amplified Output (4-20mA). With M12H connector.
1120-20 100 Amplified Output (4-20mA). With M12H connector.
1130-20 200 Amplified Output (4-20mA). With M12H connector.
1140-20 500 Amplified Output (4-20mA). With M12H connector.
1150-20 1000 Amplified Output (4-20mA). With M12H connector.
1110-30 50 Amplified Output (1-9V). With M12H connector
1120-30 100 Amplified Output (1-9V). With M12H connector
1130-30 200 Amplified Output (1-9V). With M12H connector
1140-30 500 Amplified Output (1-9V). With M12H connector
1150-30 1000 Amplified Output (1-9V). With M12H connector
1110-40 50 Amplified Output (CAN/RS485). With M12H connector
1120-40 100 Amplified Output (CAN/RS485). With M12H connector
1130-40 200 Amplified Output (CAN/RS485). With M12H connector
1140-40 500 Amplified Output (CAN/RS485). With M12H connector
1150-40 1000 Amplified Output (CAN/RS485). With M12H connector

Note for the valuable customers:

Free shipping is provided. Please contact the seller for higher quantities. 

Product has been designed, developed and manufactured under AS9100 Quality Standard. 

We are shipping from Sri Lanka: 

Express shipping with UPS/FedEx/DHL (5-7 working days)

Processing time is 10 working days.


Our Motto

Precision, Repeatable, and Reliable Measurement Solutions..!

0.08mm [.003”]