Back Box Repair Clips
Repair Damaged M3.5 Threads or Lugs in Metal Electrical Back Boxes
Repair the existing metal back box without removing it
A compact two-part metal clip designed to replace a broken faceplate-screw lug or damaged thread inside a UK metal electrical back box. It restores an adjustable M3.5 fixing point for securely refitting a socket or switch faceplate.
Choose the quantity required
Use the eBay selection box above to choose 1, 3, 5, 10 or 15 repair clips. The listing price and quantity supplied depend on the option selected.
Why use a repair clip?
  • Repairs a broken lug or stripped faceplate-screw thread
  • Avoids removing and replacing an otherwise serviceable installed metal back box
  • Push-fit design secures to the front edge of the box
  • Restores a standard M3.5 threaded fixing point
  • Allows adjustment and levelling of the fitted faceplate
  • Compact, tensioned two-piece steel construction
  • Useful for electricians, maintenance engineers and property repairs
Product specification
BrandBack Box Repair Clip
Product referenceBBRC1444
Product typeMetal back-box lug / thread repair clip
Faceplate threadM3.5
CompatibilityUK metal electrical back boxes
ConstructionTwo-part sprung and galvanised steel assembly
Approximate clip size18mm × 8mm
FinishMetal / silver
Relevant product standardsBS 4662 and BS EN 60670
Design registrationUK IPO No. 4033473
Country of originChina
Quantity options1, 3, 5, 10 or 15 clips
Basic fitting method
  1. Safely isolate the electrical supply and remove the accessory faceplate.
  2. Fully remove the damaged lug and clear any sharp edges or obstructions.
  3. Straighten the side of the metal box where required.
  4. Push the repair clip securely into position by hand or with suitable pliers.
  5. Align and refit the faceplate using the restored M3.5 fixing point.
What is supplied
The quantity of Back Box Repair Clips selected from the eBay menu: 1, 3, 5, 10 or 15 clips.
Back box, faceplate, electrical accessory and fixing screws are not included.
Installation and safety
Electrical work should be undertaken by a competent person with the circuit safely isolated, in accordance with the current edition of BS 7671 IET Wiring Regulations and all applicable requirements. Confirm the existing metal box is sound and suitable for repair. Do not strike the clip with a hammer, and do not overtighten the faceplate screw as this may damage the repair or accessory.
Huddersfield Electrical Merchants
UK stock • Carefully packed • Trade and public welcome
All orders are sent with a VAT invoice.