POWLAND MPPT SOLAR CHARGE CONTROLLER

Note: There are two batches 60A Controllers. For one batch, the fan cooling vents are located on the front side of the controller, as shown in the image. For the other batch, the fan cooling vents are located on the top side of the controller.
MPPT Solar Charge Controller

FEATURE

  • Charging 3-stage: constant current(MPPT), constant voltage(Absorption Voltage), floating charge
  • Selectable battery type Vented / Sealed / Gel / NiCd / Lithium battery (default is Sealed) (defined voltage for other battery by user)
  • Soft start time ≤1S, Dynamic response and recovery time 100us
  • Max efficiency ≥98.1%, PV utilization ≥99%
  • In order to reduce the cost of electricity caused by high current, PV and battery each have two terminals
  • MULTIPLE ELECTRONIC PROTECTIONS
  • Short-circuting
  • Reverse-current
  • Overcharging
  • Overload
  • Over-discharging
  • Reverse polarity protection
Package: 1/2/3/4pcs 60A MPPT Charger
MPPT Solar Charge Controller

Maximum PV Input Power

  • Ensure that the solar input voltage exceeds 3v or is higher than the battery voltage.
  • 12 Volt Battery Systems: Maximum PV input power 720 watts, recommended solar input voltage range 20 - 80 volts DC.
  • 24 Volt Battery Systems: Maximum PV input power 1440 watts, recommended PV input voltage range 37 - 105 VDC
  • 36 volt battery system: 2100 watt maximum PV input, recommended PV input voltage range 50 - 150 volts DC
  • 48 volt battery system: 2800 watt maximum PV input, recommended PV input voltage range 72 - 150 volts DC

Installation Procedure

6048

6048

6048

Installation Procedure

  • Install the switch between the controller and the battery.
  • Install a switch between the controller and the PV module.
  • Check that the "+" and "-" of the PV module and the "+" and "-" of the battery are correctly connected.
  • Turn on the battery switch first, then turn on the PV switch.

LCD display

  • ESC: Exit the setting without saving the data.
  • UP: Scroll down, adjust the parameter by increasing the value.
  • DOWN: Scroll up, adjust the parameter by decreasing the value.
  • ENTER: Short press to move to the next setting page, long press to exit the setting and save the data.

Display Code Meaning

Display Code Meaning

  • EQU: Load voltage compensation
  • BST: Pulse charging voltage
  • FLD: Load voltage hold
  • LDV: Over-discharge voltage
  • LRV: Over-discharge recovery voltage
  • BST - r: Pulse charge recovery voltage
  • Battery type: FLD/SEL/Gel/Lithium/Use
6048

Warning and Caution

  • 1. the battery voltage must be higher than 12v for the controller to start.
  • 2. make sure that the solar input voltage exceeds 3v or the battery voltage. 3. hold the wiring correctly and do not change the wiring.
  • 3. hold the wiring correctly and do not change the wiring. pay attention to the order of the terminal wiring.
  • 4. if it is a lead acid battery, if it is not professional, do not set any parameter, because in addition to the lithium battery, the controller also works well in the standard state.
  • 5. do not connect solar inverters / generators / wind turbines to the controller.
  • 6. Install the controller indoors to prevent the components from entering the water.
  • 7.Maximum PV input voltage (voc): 180 V dc, the controller cannot work for a long time under this voltage, which will damage the controller.
  • 8. Disconnect the battery and reconnect to save the configuration.