Number of beats (number of frequencies)
automatic
12000, 14400, 18000, 19800, 21600, 25200, 28800, 36000, 43200.
Manual selection can select the number of beats that the instrument does not automatically recognize and the number of beats that are rare.
3600,6000,7200,7380,7440,7800,9000,9100,10800,11880,12000,12342,12480,12600,13320,13440,13500,14000,14040,14160,14200,14240,1484,14240,1 14760, 14850, 118, 16200, 16320, 16800, 17196, 17258, 17280, 11786, 17897, 18000, 18049, 18514, 11332, 19440, 19800, 20160, 20222, 20944, 21000, 21031, 21306, 21600, 25200, 28800, 32400, 36000, 43200.
|
|
|
|---|---|---|
rising angle:The lift angle of most common movements is 52°, so the instrument is factory-set with a lift angle value of 52°. This value is needed when calculating the swing, and the lift angle can be set between 30° and 70°. | The measurement periods are:2s, 4s, 8s, 12s, 20s, 30s, 60s are used to calculate the average of the test results. | Key Function:A Start/Pause button Stop/Start to detect the watch B Menu/Sound button Selects the item to be adjusted and turns the speaker on or off C Numeric ↓ key Select the next lower parameter or adjust the contrast of the display during instrument testing D value ↑ button Select the last higher parameter or adjust the display contrast in the instrument test |
| Measurement range | the daily difference, swing, polarization, and lines of the mechanical watch show the time of the watch. |
| Number of frequencies: | beats for common watches can be automatically selected, or less common beats can be selected manually. |
| Daily difference measurement: | ±999 seconds/day in digital display, 1 second/day in the measurement range. |
| Swing measurement: | digital display, the division rate is 1°, the measurement range is 100°-360° (the rising angle value will affect the swing, the range is 30°-70°. Under normal circumstances, the swing range of the watch should not exceed 330°) |
| Measurement average: | 2s, 4s, 8s, 12s, 20s, 30s, 60s. |
| Polarization measurement: | The numerical unit is millisecond; the resolution is 0.1 millisecond, and the measurement range is 0.0-9.9 seconds. |
| Rise angle: | The measurement range of the rise angle is 30°—70°, and the factory setting is 52°. |
| Supply voltage: | single-phase AC 100V-240V±10% two-wire. |
| Measurement orientation: | 1-6 orientations. |
| Brand | MTST |
|---|---|
| Type of Tool | Watch Tester |
| Model | TMK-JL-3 |
| MPN | 0606267299630 |
| Country/Region of Manufacture | China |
| Measurement average | 2s, 4s, 8s, 12s, 20s, 30s, 60s |
| Supply voltage | Single-phase AC 100V-240V±10% two-wire |
| Measurement orientation | 1-6 orientations |