Applications:
The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminium, chrome etc.) on magnetic materials (e.g. iron, nickle etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminium tile, some alloy tile, paper etc.The N probes measure the thickness of non-conductivecoatings on non-magnetic metals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.
* Two measuring methods: magnetic induction (F) and eddy current (N)
* Two measurement mode: Single and Continuous(Notice:Continuous mode is convenient to measure the
coating thickness of curved objects and tiny objects.)
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Automatic memory of calibration value,and automatic recognize the substrate.
* Operation process have buzzing reminder,while no buzzing in continuous mode.
* Use “USB data output” and “RS-232 data output” to connect with PC.
* Provide “Bluetooth ™ data output” choice.
* Integral Type suitable for single-hand operation, large probe with large contact surface have better stability,
users can get continuous, good repetitive and precise measurements.
Specifications:
● Operating principle: magnetic induction/eddy current (F/NF)
●Measuring range:0-1250um/0-50mil
● Resolution; 0.1/1
● Accuracy: ±1-3%n or ±2.5um
● Min. measuring area: 6mm
● Min. sample thickness: 0.3mm
● Battery indicator: low battery indicator
● Metric/ imperial: convertible
● Power supply: 4x1.5V AAA(UM-4)battery
● Auto power off
● Operating conditions:0-+45℃(32℉-104℉),≤90%RH
● Dimensions: 126x65x27mm
● Weight: 81g(not including battery)
● Optional accessories: other range 0-200um to 15000um
Standard Accessories:
1. Main Unit
2. Calibration Base Set (F Type / NF Type) CTG-BS
3. Calibration Foils CTG-CF (1 set, 4 pieces)
4. Carrying Case
5. Operation Manual