Features:

■ Basic measurement accuracy: 0.1% 

■ Test signal frequency up to 100kHz

■ Measurement speed up to 10meas/sec

■ Large character display with bright white backlight

■ Ultra-low power consumption, battery-powered for 24 hours of continuous used             

■ Automatic identification function (Ai)

■ Constant output impedance: 100 Ohm

■ Percentage display and 4-tolerance comparator: 1%, 5%,10% and 20%

■ Automatic Open/Short correction detection

■ Data hold, Max/Min/Average recording

■ Utility function configuration and current setup recovery after power-off

■ Standard Mini-Usb interface, SCPI compatible


Accessories: 7.2V NI-MH rechargeable battery, AC adapter, Short-circuit plate, 4-terminal Kelvin test leads, SMD 4-terminla Kelvin test Tweezers, PDF manual.


Specifications:

Function

Measurement Parameters

Primary Parameters: L / C / R / Z

Second Parameters: D / Q / θ / ESR

Equivalent Circuits

Serial, Parallel

Auto LCR Function

Manual/Auto

Ranging Mode

Auto

Test Terminals

2-terminal, 4-terminal,5-terminal

Measurement Speed

10meas/sec(Fast), 5meas/sec(Medium), 2meas/sec(Slow)

Correction

Short, Open

Tolerance Mode

1%, 5%, 10%, 20%

Input protection fuse

0.1A / 250V

Interface

Mini-USB(virtual serial port)

Test Signal

Signal Frequency

100Hz, 120Hz, 1kHz, 10kHz, 100kHz

Test Signal Level

0.6Vrms

Output Impedance

100 Ω

Display

Display

LCD primary-secondary dual display

Backlight

Battery supply: when backlight is on, luminance is reduced by half 15s later and automatically turned off 30s later

Powered by adapter: backlight is on until manually turned off

Readings

Max. counts of primary parameter: 40,000; D / Q / θ Min. resolution of Secondary parameter:0.0001

Basic Accuracy

0.1%

Measurement Display Range

L

0.001uH ---  1000.0 H

C

0.001pF --- 20.000mF

R/Z

0.0001W --- 10.000MW

ESR

0.0000W -- 999.9W, resolution: 0.0001W

D

0.0000 -- 9.999, resolution: 0.0001

Q

0.0000 – 9999, resolution: 0.0001

θ

-179.9° -- 179.9°, resolution: 0.01°

Power Supply

Battery Model

7.2V Ni-MH 600mAH rechargeable battery

AC Adapter

Input: 220V(1±10%), 50Hz(1±5%);Output: 9V DC

Operating Current

Max.: 28 mA, Typical: 25mA (1kHz ,100Ω load)

Standby(Power off) Current

Max.: 2uA

Battery Life

24 hours (Typical), based on backlight off and new fully charged Ni-MH battery

Charge Time and Current

Continuous charge time: Max. 80min

Charging current: Max. 150mA

Auto Power Off

5min, 15min, 30min, 60min, OFF available

Battery Capacity indicate

Real-time display on LCD

General

Operation Condition

Temperature

0°C -- 40°C

Relative Humidity

≤ 90% R.H.

Weight

460g

Dimensions (H x W X D)

193mm x 92mm X 44mm

Safety and EMC compliance

IEC 61010-1:2001; IEC 61326-2-1:2005