■ Basic measurement
accuracy: 0.1%
■ Test signal frequency
up to 100kHz
■ Measurement speed up
to 10meas/sec
■ Large character
display with bright white backlight
■ Ultra-low power consumption,
battery-powered for 24 hours of continuous used
■ Automatic
identification function (Ai)
■ Constant output
impedance: 100 Ohm
■ Percentage display
and 4-tolerance comparator: 1%, 5%,10% and 20%
■ Automatic Open/Short
correction detection
■ Data hold,
Max/Min/Average recording
■ Utility function
configuration and current setup recovery after power-off
■ Standard Mini-Usb interface, SCPI compatible
Accessories: 7.2V NI-MH rechargeable battery, AC adapter, Short-circuit plate, 4-terminal Kelvin test leads, SMD 4-terminla Kelvin test Tweezers, PDF manual.
Specifications:
|
Function |
|||
|
Measurement Parameters |
Primary Parameters: L / C / R / Z Second Parameters: D / Q / θ / ESR |
||
|
Equivalent Circuits |
Serial, Parallel |
||
|
Auto LCR Function |
Manual/Auto |
||
|
Ranging Mode |
Auto |
||
|
Test Terminals |
2-terminal, 4-terminal,5-terminal |
||
|
Measurement Speed |
10meas/sec(Fast), 5meas/sec(Medium),
2meas/sec(Slow) |
||
|
Correction |
Short, Open |
||
|
Tolerance Mode |
1%, 5%, 10%, 20% |
||
|
Input protection fuse |
0.1A / 250V |
||
|
Interface |
Mini-USB(virtual serial port) |
||
|
Test Signal |
|||
|
Signal Frequency |
100Hz, 120Hz, 1kHz, 10kHz, 100kHz |
||
|
Test Signal Level |
0.6Vrms |
||
|
Output Impedance |
100 Ω |
||
|
Display |
|||
|
Display |
LCD primary-secondary dual display |
||
|
Backlight |
Battery supply: when backlight is
on, luminance is reduced by half 15s later and automatically turned off 30s
later Powered by adapter: backlight is
on until manually turned off |
||
|
Readings |
Max. counts of primary parameter: 40,000;
D / Q / θ Min. resolution of Secondary parameter:0.0001 |
||
|
Basic Accuracy |
0.1% |
||
|
Measurement Display Range |
L |
0.001uH --- 1000.0 H |
|
|
C |
0.001pF --- 20.000mF |
||
|
R/Z |
0.0001W --- 10.000MW |
||
|
ESR |
0.0000W -- 999.9W,
resolution: 0.0001W |
||
|
D |
0.0000 -- 9.999, resolution:
0.0001 |
||
|
Q |
0.0000 – 9999, resolution: 0.0001 |
||
|
θ |
-179.9° -- 179.9°,
resolution: 0.01° |
||
|
Power Supply |
|||
|
Battery Model |
7.2V Ni-MH 600mAH rechargeable battery |
||
|
AC Adapter |
Input: 220V(1±10%), 50Hz(1±5%);Output:
9V DC |
||
|
Operating Current |
Max.: 28 mA, Typical: 25mA (1kHz
,100Ω load) |
||
|
Standby(Power off) Current |
Max.: 2uA |
||
|
Battery Life |
24 hours (Typical), based on
backlight off and new fully charged Ni-MH battery |
||
|
Charge Time and Current |
Continuous charge time: Max. 80min Charging current: Max. 150mA |
||
|
Auto Power Off |
5min, 15min, 30min, 60min, OFF
available |
||
|
Battery Capacity indicate |
Real-time display on LCD |
||
|
General |
|||
|
Operation Condition |
Temperature |
0°C -- 40°C |
|
|
Relative Humidity |
≤ 90% R.H. |
||
|
Weight |
460g |
||
|
Dimensions (H x W X D) |
193mm x 92mm X 44mm |
||
|
Safety and EMC compliance |
IEC 61010-1:2001; IEC