Schneider Electric Telemecanique TeSys LC1D12F7 Contactor Tesys D - 3P(3 NA) - A

The description of this item has been automatically translated. If you have any questions, please feel free to contact us.


Major
RangeTeSys
TeSys Deca
Product nameTeSys D
TeSys DF
Type of product or componentConnector
Device short nameLC1D
contactor applicationresistive load
Engine control
employment categoryAC-3
AC-4
AC-1
AC-4
Number of poles3P
power pole contact composition3 NA
[Ue] Nominal operating voltagePower circuit, state 1 <= 690 V AC 25...400 Hz
Power circuit, state 1 <= 300 V direct current
[Ie] Nominal operating current25 A 60 °C) at <= 440 V AC AC-1 for power circuit
12 A 60 °C) at <= 440 V AC AC-3 for power circuit
12 A 60 °C) at <= 440 V AC AC-4 for power circuit
engine power in kW3 kW at 220...230 V AC 50/60 Hz - cable type: AC-3)
5.5 kW at 380...400 V AC 50/60 Hz - cable type: AC-3)
5.5 kW at 415...440 V AC 50/60 Hz - cable type: AC-3)
7.5 kW at 500 V AC 50/60 Hz - cable type: AC-3)
7.5 kW at 660...690 V AC 50/60 Hz - cable type: AC-3)
3.7 kW at 400 V AC 50/60 Hz - cable type: AC-4)
3 kW at 220...230 V AC 50/60 Hz - cable type: AC-4)
5.5 kW at 380...400 V AC 50/60 Hz - cable type: AC-4)
5.5 kW at 415...440 V AC 50/60 Hz - cable type: AC-4)
7.5 kW at 500 V AC 50/60 Hz - cable type: AC-4)
7.5 kW at 660...690 V AC 50/60 Hz - cable type: AC-4)
motor power HP (UL/CSA)0.5 hp at 115 V AC 50/60 Hz for 1 phase motor
2 hp at 230/240 V AC 50/60 Hz for 1 phase motor
3 hp at 200/208 V AC 50/60 Hz for 3 phase motor
3 hp at 230/240 V AC 50/60 Hz for 3 phase motor
7.5 hp at 460/480 V AC 50/60 Hz for 3 phase motor
10 hp at 575/600 V AC 50/60 Hz for 3 phase motor
control circuit typeAC at 50/60 Hz
[Uc] control circuit voltage110V AC 50/60Hz
composition of auxiliary contacts1 NO + 1 NC
[Uimp] Resistance to voltage spikes6 kV according to IEC 60947
Overvoltage categoryIII
[Ith] Conventional thermal current25 A at <60°C for power circuit
10 A at <60 °C for signaling circuit
Irms nominal connection power250 A at 440 V for power circuit according to IEC 60947
140 A AC for signaling circuit according to IEC 60947-5-1
250 A direct current for signaling circuit according to IEC 60947-5-1
Assigned cutting power250 A at 440 V for power circuit according to IEC 60947
[Icw] Allowable temporary current105 A at <40 °C - 10 s for power circuit
210 A at <40 °C - 1 s for power circuit
30 A at <40 °C - 10 min for power circuit
61 A at <40°C - 1 min for power circuit
100 A - 1 s for signaling circuit
120 A - 500 ms for signaling circuit
140 A - 100 ms for signaling circuit
associated fuse10 A gG for signaling circuit according to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuit
average impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
[Ui] Rated insulation voltagePower circuit, state 1 690 V according to IEC 60947-4-1
Power circuit, state 1 600 V CSA certified
Power circuit, state 1 600 V UL certified
Signaling circuit, state 1 690 V according to En> 40 A
Signaling circuit, state 1 600 V CSA certified
Signaling circuit, state 1 600 V UL certified
Electrical durability2 Mcycles 12 A AC-3 in Ue <= 440 V
0.8 Mcycles 25 A AC-1 at Ue <= 440 V
2 Mcycles 12 A AC-4 in Ue <= 440 V
power dissipated per pole0.36W AC-3
1.56W AC-1
0.36W AC-4
front coverWith
Mounting bracketLane
Plate
standardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
Product certificationsCCC
B.V.
CSA
G.L.
U.L.
FIGHT
GOST
LROS (Lloyds Register of Shipping)
DNV
UKCA
Connection typePower circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²flexible without cable end
Power circuit, state 1 Screw terminals 2 cable(s) 1…4 mm²flexible without cable end
Power circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²flexible with cable end
Power circuit, state 1 Screw terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²solid without cable end
Power circuit, state 1 Screw terminals 2 cable(s) 1…4 mm²solid without cable end
Control circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit, state 1 Screw terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit, state 1 Screw terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit, state 1 Screw terminals 2 cable(s) 1…4 mm²solid without cable end
tightening torquePower circuit, state 1 1.7 Nm - on screw terminals - with Ø 6 flat screwdriver
Power circuit, state 1 1.7 Nm - on screw terminals - with Philips #2 screwdriver
Control circuit, state 1 1.7 Nm - on screw terminals - with Ø 6 flat screwdriver
Control circuit, state 1 1.7 Nm - on screw terminals - with Philips #2 screwdriver
Control circuit, state 1 1.7 Nm - on screw terminals - with pozidriv screwdriver No 2
Power circuit, state 1 2.5 Nm - on screw terminals - with pozidriv screwdriver No 2
Maneuver duration12...22 ms closing
4...19 ms opening
security reliability levelB10d = 1369863 contactor cycles with rated load according to EN/ISO 13849-1
B10d = 20000000 contactor cycles with mechanical load according to EN/ISO 13849-1
Mechanical durability15 Mcycles
operating range3600 cyc/h at <60°C
Complementary
coil characteristicWithout parasitic filter as standard
control circuit voltage limits0.3...0.6 Uc -40…70 °C AC disconnection 50/60 Hz
0.8...1.1 Uc -40…60 °C operating AC 50 Hz
0.85...1.1 Uc -40…60 °C operating AC 60 Hz
1...1.1 Uc 60…70 °C operational AC 50/60 Hz
On-call consumption in VA70 VA 60 Hz 0.75 20 °C)
70 VA 50 Hz 0.75 20 °C)
maintenance consumption in VA7.5 VA 60 Hz 0.3 20 °C)
7VA 50Hz 0.3 20°C)
heat dissipation2…3 W at 50/60 Hz
type of auxiliary contactsMechanically linked type 1 NO + 1 NC according to IEC 60947-5-1
mirror contact type 1 NC according to IEC 60947-4-1
signaling circuit frequency25...400 Hz
minimum switching current5 mA for signaling circuit
minimum switching voltage17 V for signaling circuit
non-overlap time1.5 ms in de-excitation between NO and NC contact
1.5 ms in excitation between NO and NC contact
insulation resistance> 10 MOhm for signaling circuit
Power circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²flexible without cable end Power circuit, state 1 Screw terminals 2 cable(s) 1…4 mm²flexible without cable end Power circuit, state 1 Screw terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit, state 1 Screw terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit, state 1 Screw terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit, state 1 Screw terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit, state 1 1.7 Nm - on screw terminals - with pozidriv screwdriver No 2 Power circuit, state 1 2.5 Nm - on screw