| Product range | Harmony XB4 |
|---|---|
| Type of product or component | Selector |
| Device short name | XB4 |
| Bezel Material | silver chrome metal |
| Fixing ring material | Zamak |
| Mounting diameter | 22mm |
| Sold in indivisible quantities | 1 |
| Head type | Standard |
| Signal head shape | Circular |
| Operator type | Fixed |
| Operator profile | Black standard handle |
| Operator position information | 3 positions of +/- 45° |
| Type and composition of contacts | 2 NA |
| Contact operation | Slow breakup |
| Connections - terminals | Screw terminals, <= 2 x 1.5 mm² with terminal according to EN/IEC 60947-1 Screw terminals, >= 1 x 0.22 mm² without terminal according to EN/IEC 60947-1 |
| Height | 47mm |
|---|---|
| Width | 30mm |
| Depth | 68mm |
| Description of ISO n°1 terminals | (23-24)NO (13-14)NO |
| Product weight | 0.105kg |
| Resistance to high pressure washes | 7000000 Pa at 55 °C, distance: 0.1 m |
| Using contacts | Standard contacts |
| Positive opening | Without |
| Pair value | 0.14 Nm NA changing electrical state |
| Mechanical durability | 1000000 cycles |
| tightening torque | 0.8…1.2 Nm according to EN 60947-1 |
| Screw head shape | Cross compatible with Philips No. 1 screwdriver Cross compatible Pozidriv no 1 screwdriver Slotted compatible with flat 4 mm Ø screwdriver Slotted compatible with flat 5.5 mm Ø screwdriver |
| Contact material | Silver alloy (Ag/Ni) |
| Short circuit protection | 10 A Cartridge fuse type gG according to EN/IEC 60947-5-1 |
| [Ith] Conventional thermal current | 10 A according to EN/IEC 60947-5-1 |
| [Ui] Rated insulation voltage | 600 V (pollution degree 3) according to EN 60947-1 |
| [Uimp] Resistance to voltage spikes | 6 kV according to EN 60947-1 |
| [Ie] Nominal operating current | 3 A at 240 V, AC-15, A600 according to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 according to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 according to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 according to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 according to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 according to EN/IEC 60947-5-1 |
| Electrical durability | 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 according to EN 60947-5-1 annex C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 according to EN 60947-5-1 annex C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 according to EN 60947-5-1 annex C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 according to EN 60947-5-1 annex C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 according to EN 60947-5-1 annex C |
| Electrical reliability | λ < 10exp(-6) at 5 V and L/R = 1 mA in a clean environment according to EN/IEC 60947-5-4 λ < 10exp(-8) at 17 V and L/R = 5 mA in a clean environment according to EN/IEC 60947-5-4 |
| Device presentation | Complete product |