Schneider Electric Acti 9 A9C21732 ICT MAN 25A 2NA 230/240V AC

The description of this item has been automatically translated. If you have any questions, please feel free to contact us.


Major
Range of ProductActi9
Product nameACTI9 ICT +
Product type or componentConnector
Short name of the deviceICT
Device applicationLighting-Light-Motor
Poles2p
[IE] Nominal Employment Current25 A AC-7A
8.5 A AC-7B
Composition of contact poles2 na
Network typeAC
Type of controlManual and remote control
[UC] Control circuit voltage230 ... 240 V ca 50 Hz
Complementary
Network frequency50 Hz
[EU] Nominal Employment Voltage250 V AC 50 Hz
Maximum power1.2 W in 250 V AC
[UI] Nominal isolation voltage500 V AC 50/60 Hz
[UIMP] Voltage spike resistance4 kV
Control signal typeKept
switching frequency100 switching/day maneuvers
Local signsAction indicator
MAINTENANCE CONSUMPTION IN VA2,7 VA
Peak power in va9.2 VA
Type of assemblyAdjustable in clip
Assembly support35 mm symmetric din
9 mm steps2
Height81 mm
Width18 mm
Depth60 mm
ColorWhite
Mechanical durability1000000 cycles
Electric durability100000 IEC/at 61095 25 at 50 Hz AC-7A
30000 IEC/in 61095 8.5 to 50 Hz AC-7B
30000 IEC cycles/at 61095 50 Hz Category B
100000 cycles at/IEC 60947-4-1 50 Hz AC-1
30000 cycles at/IEC 60947-4-1 50 Hz AC-3
30000 cycles at/IEC 60947-4-1 50 Hz AC-5A
30000 cycles at/IEC 60947-4-1 50 Hz AC-5B
Connections - terminalsControl circuit, state 1 tunnel type terminals2 cable (s) 1.5 mm² rigid
Power circuit, state 1 tunnel type terminals1 cable (s) 1… 4 mm² flexible
Power circuit, state 1 tunnel type terminals1 cable (s) 1.5… 6 mm² rigid
Control circuit, state 1 tunnel type terminals1 cable (s) 1.5… 2.5 mm² rigid
Control circuit, state 1 tunnel terminals2 cable (s) 1.5… 2.5 mm² flexible
tightening torqueControl circuit, state 1 0.8 nm
Power circuit, state 1 0.8 nm
Product compatibilityIACTS
IACTC
IACTP
Iatet
Compatibility codeICT
Market segmentSmall shops
Residential
Around
StandardsIEC/in 61095
Noise level30 dB
heat dissipation0.9 W in 50/60 Hz
IP Protection DegreeIP20
Degree of contamination2
Tropicalization2 according to 60947-4-1
2 according to 61095
2 according to IEC 1095
relative humidity95 % in 55 ° C
Maximum operating altitude2000 m
Operating room temperature-5… 60 ° C.
Storage room temperature-40… 70 ° C.
[IE] Nominal Employment Current [EU] Nominal Employment Voltage [UI] Nominal isolation voltage [UIMP] Voltage spike resistance 100000 IEC/at 61095 25 at 50 Hz AC-7A 30000 IEC/in 61095 8.5 to 50 Hz AC-7B 30000 IEC cycles/at 61095 50 Hz Category B 100000 cycles at/IEC 60947-4-1 50 Hz AC-1 30000 cycles at/IEC 60947-4-1 50 Hz AC-3 30000 cycles at/IEC 60947-4-1 50 Hz AC-5A 30000 cycles at/IEC 60947-4-1 50 Hz AC-5B Control circuit, state 1 tunnel type terminals2 cable (s) 1.5 mm² rigid Power circuit, state 1 tunnel type terminals1 cable (s) 1… 4 mm² flexible Power circuit, state 1 tunnel type terminals1 cable (s) 1.5… 6 mm² rigid Control circuit, state 1 tunnel type terminals1 cable (s) 1.5… 2.5 mm² rigid Control circuit, state 1 tunnel terminals2 cable (s) 1.5… 2.5 mm² flexible Control circuit,