BioLabTek eBay Template
BioLabTek

Molecular PCR Testing

BioFire FilmArray Torch | Base and 6 Modules

High-performance multiplex PCR system

QC PASS Tested & Working

At a glance

Manufacturer
BioFire Diagnostics
Model
FilmArray Torch
Part / Catalog #
Base: HTFA-ASY-0104
Modules: HTFA-SUB-0103
Serial #
Base: TB03172
Modules: TM04720, TM04738, TM00074, TM17723, TM06264, TM19334
Condition
Used, Excellent

What's Included

  • BioFire FilmArray Torch System Base (HTFA-ASY-0104)
  • 6 Modules (HTFA-SUB-0103)
  • Power Cable
  • Nothing else is included unless shown in

Specifications

Sample descriptionOne sample capacity per module (with up to 12 samples per BIOFIRE Torch)
Run timeSample run time about one hour
User interfaceSystem base with touch screen and barcode scanner
Data outputAutomatic analysis with end-of-run interpretive reports
Fluorescence acquisitionSingle color optics module: 475 nm excitation, 545 nm emission, and sensor imaging
Temperature controlOperating temperature 15°C to 30°C; Peltier devices: ambient to 100°C, ramp rate from 0.1–0.5°C/sec on melt
Operations specification15°C to 30°C @ 20 to 80% relative humidity (non-condensing); –16 m to 3048 m; indoor use only
Shipping specifications-30°C to 38°C @ 5 to 85% relative humidity (non-condensing); -16 m to 10,600 m
Power requirements – minimum (single module)100–240 VAC, 50–60 Hz; AC power at 100 VAC: 130W active, 135VA apparent; AC power at 240 VAC: 110W active, 190VA apparent; grounded outlet requirements
Power requirements – maximum (12 modules)100–240 VAC, 50–60 Hz; AC power at 100 VAC: 850W active, 935VA apparent; AC power at 240 VAC: 775W active, 1100VA apparent; grounded outlet requirements
Fuse250V 3.15A Type T (modules); 250V 10A Type T (system base)
Dimensions and weight18 × 29 × 11.5 in (45.8 × 73.7 × 29.2 cm) (W × D × H; system base only); 4.5 in (11.4 cm) (H; modules only); 34 in (86.4 cm) max height (12 modules); weight: approximately 28 lb (12.6 kg) maximum, system base 36 lb (16.3 kg), modules 1.5 lb (6.8 kg) each; duplex (module enclosure) 6.5 lb (~3 kg) each
EMC requirementsThe BIOFIRE TORCH complies with the emission and immunity requirements in IEC 61326: electrical equipment for measurement, control and laboratory use
Safety requirementsThe BIOFIRE TORCH complies with IEC 61010-1-201: safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-101: particular requirements for in vitro diagnostic (IVD) medical equipment
CPUIntel
Storage and memory512 GB hard drive or greater; 16 GB RAM or greater
Interface and peripheralsSystem base: 12+1 Ethernet network interface, 4 USB connections or more; module: one Ethernet network interface
DisplayLCD: capacitive touch screen interface
Operating systemMicrosoft Windows OS as released with the BIOFIRE System

Specs from manufacturer literature for reference. Verify against your application.

Terms & Conditions

Payment

  • We accept most payment types and work with your organization's accounting requirements.
  • Contact us if you need a formal quote or to procure with a PO.

Shipping

  • Items ship within 1 to 2 business days after cleared payment.
  • We ship via USPS, FedEx, UPS, or freight, to the contiguous USA and worldwide.
  • Worldwide buyers are responsible for customs and duty import charges.
  • Need expedited service or billing to your own FedEx or UPS account? Tell us at purchase.
  • You may arrange your own shipping through your own carrier on request.

Return Policy

  • 60-day returns on all products from time of delivery.
  • If anything is not right, contact us first. We want you fully satisfied.

Why BioLabTek

  • We power on and function-test, then document what we saw
  • Photos show the exact unit you receive
  • Instruments packed to survive the carrier
  • POs and formal quotes welcome for academic and corporate buyers
BioLabTek  |  Laboratory Equipment Specialists  |  © 2026 BioLabTek