Input current
|
|
from backplane bus 5 V DC, max.
|
90 mA
|
|
Power loss
|
|
Power loss, typ.
|
0.4 W
|
|
Analog inputs
|
|
Number of analog inputs
|
8
|
|
Number of analog inputs for resistance measurement
|
8
|
|
permissible input voltage for voltage input (destruction limit), max.
|
30 V; 12 V continuous, 30 V for max. 1 s
|
|
permissible input current for current input (destruction limit), max.
|
40 mA
|
|
Input ranges
|
|
Voltage
|
Yes
|
|
Current
|
Yes
|
|
Thermocouple
|
No
|
|
Resistance thermometer
|
Yes
|
|
Resistance
|
Yes
|
|
Input ranges (rated values), voltages
|
|
0 to +10 V
|
Yes
|
|
Input resistance (0 to 10 V)
|
100 kO
|
|
1 to 5 V
|
Yes
|
|
Input resistance (1 to 5 V)
|
100 kO
|
|
1 to 10 V
|
No
|
|
-1 V to +1 V
|
Yes
|
|
Input resistance (-1 V to +1 V)
|
100 kO
|
|
-10 V to +10 V
|
Yes
|
|
Input resistance (-10 V to +10 V)
|
100 kO
|
|
-2.5 V to +2.5 V
|
No
|
|
-250 mV to +250 mV
|
No
|
|
-5 V to +5 V
|
Yes
|
|
Input resistance (-5 V to +5 V)
|
100 kO
|
|
-50 mV to +50 mV
|
Yes
|
|
Input resistance (-50 mV to +50 mV)
|
100 kO
|
|
-500 mV to +500 mV
|
Yes
|
|
Input resistance (-500 mV to +500 mV)
|
100 kO
|
|
-80 mV to +80 mV
|
No
|
|
Input ranges (rated values), currents
|
|
0 to 20 mA
|
Yes
|
|
Input resistance (0 to 20 mA)
|
100 O
|
|
-10 to +10 mA
|
No
|
|
-20 to +20 mA
|
Yes
|
|
Input resistance (-20 to +20 mA)
|
100 O
|
|
-3.2 to +3.2 mA
|
No
|
|
4 to 20 mA
|
Yes
|
|
Input resistance (4 to 20 mA)
|
100 O
|
|
Input ranges (rated values), thermocouples
|
|
Type B
|
No
|
|
Type E
|
No
|
|
Type J
|
No
|
|
Type K
|
No
|
|
Type L
|
No
|
|
Type N
|
No
|
|
Type R
|
No
|
|
Type S
|
No
|
|
Type T
|
No
|
|
Type U
|
No
|
|
Type TXK/TXK(L) acc. GOST
|
No
|
|
Input ranges (rated values), resistance thermometers
|
|
Cu 10
|
No
|
|
Ni 100
|
Yes; Standard/climate
|
|
Input resistance (Ni 100)
|
100 MO
|
|
Ni 1000
|
Yes
|
|
Input resistance (Ni 1000)
|
100 MO
|
|
LG-Ni 1000
|
Yes; Standard/climate
|
|
Input resistance (LG-Ni 1000)
|
100 MO
|
|
Ni 120
|
No
|
|
Ni 200
|
No
|
|
Ni 500
|
No
|
|
Pt 100
|
Yes; Standard/climate
|
|
Input resistance (Pt 100)
|
100 MO
|
|
Pt 1000
|
No
|
|
Pt 200
|
No
|
|
Pt 500
|
No
|
|
Input ranges (rated values), resistors
|
|
0 to 150 Ohm
|
No
|
|
0 to 300 Ohm
|
No
|
|
0 to 600 Ohm
|
Yes
|
|
Input resistance (0 to 600 Ohm)
|
100 MO
|
|
0 to 6000 Ohm
|
Yes
|
|
Input resistance (0 to 6000 Ohm)
|
100 MO
|
|
Thermocouple (TC)
|
|
Characteristic linearization
|
|
for thermocouples
|
No
|
|
Temperature compensation
|
|
parameterizable
|
No
|
|
internal temperature compensation
|
No
|
|
external temperature compensation with compensations socket
|
No
|
|
Resistance thermometer (RTD)
|
|
Characteristic linearization
|
|
for resistance thermometer
|
yes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.
|
|
Characteristic linearization
|
|
parameterizable
|
Yes
|
|
Cable length
|
|
Cable length, shielded, max.
|
200 m; max. 50 m at 50 mV
|
|
Analog value generation
|
|
Measurement principle
|
integrating
|
|
Integration and conversion time/resolution per channel
|
|
Resolution with overrange (bit including sign), max.
|
13 bit
|
|
Integration time, parameterizable
|
Yes; 60 / 50 ms
|
|
Basic conversion time, ms
|
66 / 55 ms
|
|
Interference voltage suppression for interference frequency f1 in Hz
|
50 / 60 Hz
|
|
Encoder
|
|
Connection of signal encoders
|
|
for current measurement as 2-wire transducer
|
Yes; with external supply
|
|
for current measurement as 4-wire transducer
|
Yes
|
|
for resistance measurement with two-wire connection
|
Yes
|
|
for resistance measurement with three-wire connection
|
Yes
|
|
for resistance measurement with four-wire connection
|
Yes
|
|
Errors/accuracies
|
|
Operational error limit in overall temperature range
|
|
Voltage, relative to input area, (+/-)
|
0.6 %; +/-0.6% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); +/-0.5% (+/-50 mV, 500 mV, 1 V)
|
|
Current, relative to input area, (+/-)
|
0.5 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA
|
|
Resistance, relative to input area, (+/-)
|
0.5 %; 0 to 6 kohms, 0 to 600 kohms
|
|
Resistance thermometer, relative to input area, (+/-)
|
1 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic); 1.2 Kelvin (Pt100, Ni100, standard)
|
|
Basic error limit (operational limit at 25 °C)
|
|
Voltage, relative to input area, (+/-)
|
0.4 %; 0.4% (+/-5 V, 10 V, 1 to 5 V, 0 to 10 V); 0.3% (+/-50 mV, 500 mV, 1 V)
|
|
Current, relative to input area, (+/-)
|
0.3 %; +/-20 mA, 0 to 20 mA, 4 to 20 mA
|
|
Resistance, relative to input area, (+/-)
|
0.3 %; 0 to 6 kohms, 0 to 600 kohms
|
|
Resistance thermometer, relative to input area, (+/-)
|
1 Kelvin (Pt100, Ni100, standard); 0.8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic)
|
|
Isochronous mode
|
|
Isochronous mode (application synchronized up to terminal)
|
No
|
|
Interrupts/diagnostics/status information
|
|
Alarms
|
|
Diagnostic alarm
|
No
|
|
Limit value alarm
|
No
|
|
Diagnostic messages
|
|
Diagnostic functions
|
No
|
|
Diagnostic information readable
|
No
|
|
Diagnostics
|
No
|
|
Group error
|
No
|
|
Diagnostics indication LED
|
|
Group error SF (red)
|
No
|
|
Galvanic isolation
|
|
Galvanic isolation analog inputs
|
|
between the channels
|
No
|
|
between the channels and the backplane bus
|
Yes
|
|
Isolation
|
|
Isolation tested with
|
500 V DC
|
|
Connection method
|
|
required front connector
|
40-pin
|
|
Dimensions
|
|
Width
|
40 mm
|
|
Height
|
125 mm
|
|
Depth
|
117 mm
|
|
Weights
|
|
Weight, approx.
|
250 g
|