Specifications
Model PMC71-UCC1M2AFAAA
S/N: A9022D1509C
Made In UNITED STATES
Condition Surplus New
Dimensions 8.5(H) x 9(W) x 14(L) inches
Weight 23.14855641193 lbs
Other Specifications

Measuring Principle: Absolute and gauge pressure

Characteristic: Digital transmitter with capacitive sensor and ceramic membrane, modular transmitter, long term stability, enhanced safety via self diagnostic functions, secondary process barrier

Supply Voltage: 4-20 mA HART, 10.5-45 VDC (Non Ex): Ex ia: 10.5-30 VDC, PROFIBUS PA: 9-32 VDC (Non Ex), FOUNDATION Fieldbus: 9-32 VDC (Non Ex)

Reference Accuracy: Standard: 0.05%, Platinum: up to 0.025%

Long Term Stability: 0.05% of URL/year, 0.08% of URL/5 year, 0.1% of URL/10 year

Process Temperature: -20 deg. C to 150 deg. C (-4 deg. F to 257 deg. F)

Ambient Temperature: -40 deg. C to 85 deg. C (-40 deg. F to 185 deg. F)

Measuring Cell: 100 mbar-40 bar (1.5 psi to 600 psi) relative/absolute

Smart Calibratable Span: 5 mbar (0.075 psi)

Vacuum Resistance: 0 mbar abs.

Maximum Turn Down: 100:1

Maximum Overpressure Limit: 60 bar (900 psi)

Process Connection: Thread: G1/2-G2, R1/2, MNPT 1/2-MNPT2; Flange: DN25-DN80, ASME 1"-4", JIS 10K

Process Connection Hygienic: Tri-Clamp DIN11851 Varivent N SMS DRD

Material Process Membrane: Ceramic

Material Gasket: Viton, EPDM, Chemraz, Kalrez, NBR

Fill Fluid: none, dry measuring cell

Material Housing: Die-cast aluminum AISI 316L

Communication: 4-20 mA HART PROFIBUS PA FOUNDATION Fieldbus


Request total from seller: Look for the "Request total from seller" link or button on the shopping cart page. From there, we'd be able to send an invoice with an accurate shipping cost through Canada Post and FedEx! Review and Pay: Once you receive the updated invoice from us, review it to make sure the shipping address is correct. If everything looks good, you can proceed to pay for the items, and we'll have it shipped as soon as possible!