| Basic Specifications | Accuracy guarantee period: 1 year |
|---|
| Resistance Measurement Range | 3 mΩ (maximum display 3.100 mΩ, resolution 1 Ω) to 3 Ω range (maximum display 3.100 Ω, resolution 1 mΩ), 4 switching Measurement accuracy: ±0.8% rdg ±6 dgt (3 mΩ range only ±1.0% rdg ±8 dgt) Measurement current frequency: 1 kHz ±30 Hz, 1 kHz ±80 Hz when noise frequency avoidance function is enabled Measurement current: 160 mA (3 mΩ/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range) Open terminal voltage: 5 V max. |
|---|
| Voltage Measurement Range | ±6 V (maximum display ±6.000 V, resolution: 1 mV) to ±60 V (maximum display ±60.00 V, resolution: 10 mV), 2 switching, measurement accuracy: ±0.08% rdg ±6 dgt |
|---|
| Temperature Measurement Accuracy | Measurement range -10°C to 60°C, Maximum display 60.0°C, Resolution 0.1°C, Measurement accuracy* ±1.0°C *When using the 9460 Clip-type Lead with Temperature Sensor *When using the 9451 Temperature Probe, add ±0.5°C (cable length 1.5 m) *When using the 9451s Temperature Probe, add ±0.5°C (cable length 0.1 m) Accuracy for BT3554-50 alone: With dummy input: ±0.5°C |
|---|
| Maximum Allowable Input Voltage | DC 60 V max. AC input not possible |
|---|
| Measurement time | 100ms |
|---|
| Response Time | Approximately 1.6 seconds |
|---|
| comparator | Comparison of set threshold and measured value, judgement, notificationJudgment notification method: Results display (segment), buzzer sound as shown in the following table. For high voltage value: Resistance value (low) = PASS, Resistance value (medium) = WARNING, Resistance value (high) = FAIL. For low voltage value: Resistance value (low) = WARNING, Resistance value (medium) = WARNING, Resistance value (high) = FAIL. When the judgement result is WARNING or FAIL, the buzzer sounds and the red backlight turns on. Set voltage judgement method: ABS (absolute value judgement), POL (judgement with ± polarity). Settings saved: 200 tables |
|---|
| Memory function | Operation: Save, read and delete measurement data, Save and delete profile information, Number of data: 6000, Memory configuration: 500 data per unit (12 units) Saved contents: Save measurement data and profile information in association with each other 1. Measurement data: Can be saved, read and deleted using the main unit -1. Date and time -2. Resistance value, voltage value, temperature -3. Comparator threshold value, judgment result
2. Profile information: Can be saved, read and deleted using compatible applications (GENNECT Cross / GENNECT ONE) -1. Profile number: 1 to 100 (the following 2. 3. 4. are saved for each profile number) -2. Location information: Arbitrary comment such as the location of the UPS -3. Device information: Arbitrary comment such as the UPS management number -4. Battery number: Numbers from 1 to 500 (start number, end number) |
|---|
| Measurement Recording Guide | Operation: Notifies the battery number to be measured next time by display on the main unit screen and voice. * Voice is output from smartphone/tablet when using Z3210 and compatible application (GENNECT Cross). Advance preparation: Transfer profile information registered in compatible application (GENNECT Cross / GENNECT ONE) to the main unit. |
|---|
| Communication Interface | USB Bluetooth®? wireless communication (when Z3210 is installed) |
|---|
| Other features | Temperature measurement (-10.0℃ to 60.0℃), zero adjustment, hold, auto hold, auto memory, auto power save, clock |
|---|
| power supply | 8 AA alkaline batteries (LR6) Continuous use time: Approx. 8.3 hours (Z3210 not installed), Approx. 8.2 hours (Z3210 installed, wireless communication) |
|---|
| Dimensions and weight | 199W x 132H x 60.6D mm (with protector attached), 960 g (including battery and protector) |
|---|
| accessories | Carrying case C1014 ×1, Protector Z5041 ×1, Fuse set Z5050 ×1, Zero adjustment board ×1, Neck strap ×1, USB cable ×1, Application software GENNECT One CD-R ×1, AA alkaline battery (LR6) ×8, Instruction manual ×1 |
|---|
| Notes | The actual color may differ from the images depending on the color reproduction of your monitor. Please note that specifications and appearance may be changed without notice for product improvement. BT3554-50 does not come with a probe. |
|---|