Main technical and operational characteristics of B2B-1B:
• the working operating voltage @ 30 MHz...... 4 kV
• the passed current @ 30 MHz...... 15 A
• switching voltage ...... 6-16 V
• release voltage ...... 1 V
• reaction time...... 35 ms
• the number of switching cycles, not less: 100000
• switching frequency, no more: 1 Hz
• electric resistance of contacts...... 0,015 Ohms
• winding resistance...... 180-200 Ohms
• electric durability of a winding...... 500 V
• temperature range......-60 … 100 C
Limit values of permissible operating conditions:
• Maximum permissible voltage @ 3 MHz (rms) ..... 5.5 kV
•
Maximum permissible current @ 3 MHz (rms) .................. 35A
•
DC voltage on the control winding, ............................ 27 (-5 ..+ 3) V