KINGDOM LED UK SELLER

Applications

- Low voltage lighting system
- HVAC control circuit
- Junction boxes in wall or ceiling
- Mobile homes

 Junction Box Push Wire Connectors

Available in 2, 4, 6 and 8 pole, these colour coded connectors are suitable for 0.75mm to 2.5mm solid and 1.5mm to 2.5mm stranded cables. The new 3 pole version is suitable for solid and stranded cables from 1.5mm to 6mm.

Simply pushing the stripped cable into the connector makes the connection; the transparent housing, a feature of all the connectors in the range, provides a visible indication that the cable is secure.

There is a test point in the housing. The cables are removed by holding the wire and twisting left/right while pulling on the connector, which means the connector can be re-used. Also available is a fixing carrier that is designed to secure the connectors into a junction box or onto DIN rail. The rating is 400V, 24A and 41A for 3 pole version.

PCT-102
No. of Poles  
Total number of connection points  
Total number of potentials  
Color transparent  
Pollution degree (1)  
Rated voltage EN (1) [V] 400 
Rated surge voltage (1) [kV] kV 
Nominal current [A] 24 
Connection technology (1) PUSH WIRE®  
Solid sizes 1 0.75 … 2.5 mm² / 18 … 12 AWG  
Strip length 1 12 mm / 0.47 in  
Type of wiring Side-entry wiring  
Weight [g] 1.847 
Width 9.2 mm / 0.362 in  
Height 13.1 mm / 0.516 in  
Length 19.5 mm / 0.768 in  
Safety information 1 In grounded power lines 


 

PCT-104

Total number of connection points  
Total number of potentials  
Color transparent  
Pollution degree (1)  
Rated voltage EN (1) [V] 400 
Rated surge voltage (1) [kV] kV 
Nominal current [A] 24 
Connection technology (1) PUSH WIRE®  
Solid sizes 1 0.75 … 2.5 mm² / 18 … 12 AWG  
Strip length 1 12 mm / 0.47 in  
Type of wiring Side-entry wiring  
Fire load [MJ] 0.057 MJ 
Weight [g] 2.677 
Width 13 mm / 0.512 in  
Height 13.1 mm / 0.516 in  
Length 19.5 mm / 0.768 in  
Safety information 1 In grounded power lines  

PCT-106

Total number of connection points  
Total number of potentials  
Color transparent  
Pollution degree (1)  
Rated voltage EN (1) [V] 400 
Rated surge voltage (1) [kV] kV 
Nominal current [A] 24 
Connection technology (1) PUSH WIRE®  
Solid sizes 1 0.75 … 2.5 mm² / 18 … 12 AWG  
Strip length 1 12 mm / 0.47 in  
Type of wiring Side-entry wiring  
Weight [g] 4.25 
Width 18.8 mm / 0.74 in  
Height 13.1 mm / 0.516 in  
Length 19.5 mm / 0.768 in  
Safety information 1 In grounded power lines  

PCT-108

Total number of connection points  
Total number of potentials  
Color transparent  
Pollution degree (1)  
Rated voltage EN (1) [V] 400 
Rated surge voltage (1) [kV] kV 
Nominal current [A] 24 
Connection technology (1) PUSH WIRE®  
Solid sizes 1 0.75 … 2.5 mm² / 18 … 12 AWG  
stranded, connectable 1 1.5 … 2.5 mm² / 16 … 12 AWG  
Strip length 1 12 mm / 0.47 in  
Type of wiring Side-entry wiring  
Fire load [MJ] 0.098 MJ 
Weight [g] 4.605 
Width 24 mm / 0.945 in  
Height 13.1 mm / 0.516 in  
Length 19.5 mm / 0.768 in  
Safety information 1 In grounded power lines  

Product will be supplied loose not in a box

FAQs


Should KINGDOM connectors be used in an enclosure?
In order to comply with the requirements of the 16th Edition of the IEE Wiring Regulations/BS7671, all connectors should be used in a suitable enclosure of material complying with the relevant glow-wire test requirements of BS 458-2.1. (Fire hazard testing for electrotechnical products). This will provide
mechanical protection for the connectors as well as protection against dust, damp and accidental damage. Although WAGO connectors are IP20 (finger touch) with Polyamide 6.6 housing for strength and durability.

Do they need to be fixed in an enclosure?
The junction box connectors do not have to be fixed down in the housing provided that the cables are secured on their way into the box. However, fixing provides a more secure and professional looking finish.

Does there need to be strain relief on the cable?
Yes, there should be strain relief on the cable. This could be the cable clipped outside the enclosure or cable glands within the enclosure to prevent the cables being pulled out of the connectors.

I'm used to screw connections - how secure is your clamping system?
The KINGDOM Cage Clamp? and PushWire clamping systems guarantee gastight, maintenance-free connections every time. Our connectors incorporating these proven technologies have been used in industrial and building services applications worldwide. The company's reputation is built on the high quality and proven performance of our products. For installers, this ensures complete peace of mind.

How do I release the conductor from the terminal?
All KINGDOM connectors are re-usable. PushWire conductors are removed by pulling the conductor and twisting the connector. Cage Clamp? connections are released by using a screwdriver or pushbutton/lever operation.

Do your connectors comply with British Standards?
BSI recognise and harmonise with IEC 60947, 60998 and 60999. These are European standards which relate to terminal blocks and connectors. All KINGDOM products conform to these standards and other international requirements.


There's a small cavity in a ceiling, wall or floor. Can a terminal block be fitted without the need for an additional back box?
Yes. When installing backless equipment, such as a domestic style luminary, it is possible for the enclosure to be formed or completed with building material considered to be non-combustible when tested to BS 476-4. (Fire tests on building materials and structures. Non-combustibility tests for materials). Where there is any doubt that the building material does not meet this standard, the electrical connections should be shielded from the fabric of the building by a suitable electrical back-box.




Please read and note the following before ordering:

1)Please contact me if you have a feedback score of less then 5 before bidding for approval
2) I will only ship to a confirmed UK paypal address - OTHERWISE I WILL NOT SHIP IT
3) My Shipping is for UK Mainland ONLY. Some areas may incur additional costs
4) Please ensure you have a valid contact phone number registered with Ebay, I will pass this number onto the Carrier for delivery. No refunds for carriage will be offered if delivery is delayed as a result of no contact number being provided.
5) I Welcome collections but will only accept cash on collection
6) I am unable to provide any technical support, please ensure you fully understand how this item works by checking for any datasheets (not provided with the item) , to enable the product to be used within your application / project.
7) When upgrading to 1st class post, please note this is sent via Royal Mail and is not a guaranteed next working day service. If you need a next working day (not weekend or bank holiday) service please select courier delivery.
8) We attempt to send out all orders received before 2.00pm. This excludes weekends and public holiday.
9) Customers placing multiple orders. - I may ship all the orders as one, please do not ask for a refund of shipping cost after you have placed your orders. Please do not place your orders if you want a refund of shipping cost.

**** Important note ****:Some sellers claim the stock is in the UK, please be careful, the seller is often in China and sends the item to a UK agent who then forwards the item on with a UK stamp. Check where the seller is located not just the item location. All my items are physically with me in the UK and I offer a quick delivery and communication within the UK. All UK businesses display their physical address on the main listing page at the bottom "Business seller information".