Thermo Scientific HERAcell VIOS 250i
This item was removed from a facility where it was surplus to requirement.
In good working order.
Last Service: 18/06/2024
Incubators may be transported via a range of delivery methods, including palletised courier networks or direct delivery to the intended location of use. During transit, internal sensors, fans, or control systems may be affected by vibration or movement.
To ensure optimal performance and accurate environmental conditions, it is essential that all incubators are allowed to stabilise upon arrival and are professionally calibrated before first use. Calibration ensures the unit reaches and maintains the desired temperature, humidity, or CO₂ levels reliably.
Please ensure: - The unit is left for a minimum of 12 hours upright and unpowered after delivery. - Calibration is completed in accordance with manufacturer specifications before any use.
Failure to calibrate prior to use may result in inaccurate conditions and affect experimental integrity or compliance with laboratory standards.
NOTE: No cables, remotes, accessories, power supplies, consumables or any other item is included unless shown in the item photo or is in the item description.
Item Details
| Property |
Value |
Tested value |
|---|
| Type |
Floorstanding |
|
| Heating Method |
Unspecified |
|
| Refrigeration |
Yes |
|
| Refrigerant |
R134a |
|
| CO2 Sensor Type |
IR Sensor |
|
| With Hot Air Sterilisation |
Yes |
|
| Humidifier |
Natural Evaporation from Humidifying Pan |
|
| With UV Lamp |
N/A |
No |
| PAT Test |
| Electrical Supply |
N/A |
1-Phase |
| Plug Included? (1-Phase) |
N/A |
Yes - Standard UK 3-Pin Mains Plug (BS 1363) |
| PAT Test Result |
N/A |
Pass |
| Voltage |
N/A |
240V |
| PAT Test Date |
N/A |
09-03-2026 |
| Recertification Initial Checks |
| Overall Cosmetic Condition |
N/A |
Good |
| Safety Features |
| Emergency Stop Safety Check |
N/A |
N/A |
| Service Details |
| Last Service Date |
N/A |
18/06/2024 |
| Other Details |
| Year of Manufacture |
N/A |
2019 |
| Configuration |
N/A |
Single Unit |
| Physical Specifications |
| Minimum Temperature (ºC) |
Ambient +3 |
|
| Maximum Temperature |
55 |
|
| Interior Volume (L) |
255 |
|
This item is only suitable for pallet delivery. Delivery will be made to kerbside only, unless otherwise confirmed in writing. The listed price is for economy delivery (3-5 working days) to mainland UK addresses excluding Northern Ireland and the following postcodes, where surcharges may apply - please enquire before ordering.
AB31-38, AB40-52, AB54-56, AB63 IV1-28, IV30-32, IV36-56, IV63, KA27-28, KW1-17, PA20-38, PA41-49, PA60-78, PH4-44, PH49-50, PO30-41, TR21-25, BT, GS, GY, HY, IM, JE, TDCU, ZE
International buyers
Therefore please contact us so we can discuss what other costs you may incur with shipment such as import VAT and customs duties. In some cases, we may need to apply for export licenses which can take some time; we can advise on time-scales.
It is always best to contact us for a quote/timescale prior to ordering, as in some cases we may be able to offer reduced postage costs and/or other options.
You are also welcome to arrange your own courier subject to regulatory and documentation requirements.
For international orders where we ship to you our default Incoterms are DAP unless otherwise agreed.
Return Policy
Buy with confidence. If you wish to return the item, for whatever reason, you may do so within 45 days.
VAT and Purchase Orders
In some cases we may be able to zero rate the VAT for charity-funded equipment and other exemptions. Please enquire for further details.
For all buyers outside of the UK, the price shown is exclusive of VAT. For any uncertainties, please contact us before bidding.
Universities and colleges - purchase orders accepted - please contact us.
FDA Disclaimer:
For buyers in the US, and any other regions where FDA regulations may apply, please be aware of the following FDA Disclaimer.
"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser.
Please be aware of the FDA Website.
Seller information relating to the above FDA Disclaimer:
Sellers’ name is Universal Resource Trading Ltd, of Unit 24, Sir Alfred Owen Way, CF83 3HU, United Kingdom.
Sellers’ contact number is 02920 864661.
Seller confirms the item is used, but has been cleaned and handled in accordance with the manufacturer’s instructions.
SKU: ITEM-51778
|
About Us
We are a family business located and have been involved in the resale of surplus items for over three decades.
We sell surplus equipment and items on behalf of a large companies, research institutes and universities.
All of our products are collected by our team as assets for resale - and come straight out of an office, laboratory or other working environment.
We do not source any items from waste disposal. Therefore you can be confident in our products.
|
|