Handheld Dew Point Meters With Range -45~120°C/-49~248°F Max Min Function

Note:Batteries not included in shipping!!!

  • Large LCD with display. It can display three values at the same time.
  • Support multi-parameter measurement of ambient temperature, dew point temperature, wet bulb temperature, relative humidity.
  • Temperature unit (°C/°F).
  • 0.01 high resolution.
  • With data storage function (99 Groups).
  • With maximum, minimum function.
  • With data hold function.
  • With battery indication function.
  • With automatic power off function.
Features
1. Large LCD with display. It can display three values at the same time.
2. Ambient Temperature measurement.
3. Dew Point Temperature measurement.
4. Wet Bulb Temperature measurement.
5. Relative Humidity measurement.
6. Temperature unit (°C/°F).
7. 0.01 high resolution.
8. With data storage function (99 Groups).
Introduction
It is a professional portable dew point meter. It is able to measure Ambient Temperature, Dew Point Temperature, Wet Bulb Temperature, Relative Humidity. It can quickly respond to temperature and humidity measurements in the industrial range. It is also capable of measuring temperature and humidity in a variety of complex environments. Widely used in workshops, warehouses, libraries, offices, computer rooms, laboratories and other environmental temperature and humidity monitoring occasions.

 Display

 LCD

 Test Parameters

 Ambient Temperature, Relative Humidity, Dew Point TemperatureWet Bulb Temperature

 Ambient Temperature

 Range

 -30~120°C (-22~248°F)


 Accuracy

 ± 0.4°C (90~120°C)

 ± 0.2°C (60~90°C)

 ± 0.1°C (20~60°C)

 ± 0.2°C (-30~20°C)


 Resolution

 0.01 (<100)

 0.1 (Other)

 Relative Humidity

 Range

 0~100%RH


 Accuracy

 ± 1.5%RH (0~80%RH)

 ± 2%RH (80~100%RH)


 Resolution

 0.01

 Dew Point Temperature

 Range

 -45~120°C (-49~248°F)


 Resolution

 0.01 (<100)

 0.1 (Other)

 Wet Bulb Temperature

 Range

 -20~40°C (-4~104°F)


 Resolution

 0.01 (<100)

 0.1 (Other)

 Temperature Unit

 °C/°F

 Storage

 99 Groups (Manual Storage)

 Statistical Functions

 Maximum, Minimum

 Automatic Power Off

 10 Minutes (No Operation)

 Operating Conditions

 Temperature0~50°CHumidity0~80%RH (No Condensation)

 Storage Conditions

 Temperature-10~60°CHumidity0~90%RH (No Condensation)

 Power Supply

 4 × 1.5V AAA(UM-4) Battery (not included)

 Size

 205×80×31mm

 Weight

 182g (Not Including Batteries)

 Standard Accessories

 Main Unit ×1


 Manual ×1


 Carrying Case ×1