Power Quality Analyzer Three Phase Power Quality Meter with Accuracy 0.5 Grade
Introduction:
Main Function:
Features:
Specifications:
Power Supply | Rechargeable lithium battery 7.4V, external charger |
Battery Indicator | Battery symbol shows power energy. When the voltage is too low, automatic shutdown |
Working Current | About 490 mA |
Instrument Dimension | 240mmX170mmX68 mm |
Display Mode | 5inch touch colorful screen |
Current | Current clamp: 10mA~10A |
Clamp Current Sensor CT Size | 17*18mm |
Frequency | 40Hz~70Hz. |
Harmonic | Yes, 2~51 orders |
Total Harmonic Distortion | Yes, 2~51orders, each phase |
Three-phases Unbalance | Yes. |
Communication Interface | USB |
Language | Switch between Chinese and English |
Automatic Shutdown | In recording mode, the instrument will not automatic shutdown |
When not in recording mode, can set the automatic shoutdown time after 15minutes,30minutes,60minutes according to request | |
Automatic Shutdown | In the alarm mode/trend chart record mode/transient capture mode (waiting or in progressing), the instrument will not automatic shutdown |
In other test mode, within 15 minutes without keystrokes operation, automatic shutdown after prompt 1 minute. | |
Weight | Host: 900g (with battery). |
Clamp current sensor: 510gX4 | |
Test lines: 400g; | |
Total weight: about 8kg (with all accessories). | |
Memory Card | 4G(expandable up to 32G) |
Voltage Test Line Length | 3m |
Current Sensor Line Length | 2m |
Working Temperature | -10°C~40°C; below 80%Rh. |
Storage Temperature | -10°C~60°C; below 70%Rh. |
Input Impedance | Input impedance of test voltage: 1MΩ. |
Withstand Voltage | Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and housing. |
Insulation | Between instrument wiring and shell ≥10MΩ. |
Structure | Double insulation, with insulation vibration-proof sheath. |
Suitable Safe Standard | IEC 61010 Cat III 1000V /CAT IV 600V , IEC61010-031, IEC61326, Pollution degree 2 |
Measurement | Range | Display Resolution | The Max Error In Reference Range |
Frequency | 40Hz~ 70Hz | 0.001Hz | ±(0.01)Hz |
Phase Voltage True RMS | 2V~ 600V | Min resolution 0.001V | ±(0.5%rdg) |
Current True RMS | 10mA~ 6000A | Min resolution 0.001A | ±(0.5%rgt) |
Active Power | 0.0000W~ 3600kW | Min resolution 0.001W | ±(1%+3dgt) Cosφ≥0.8 |
±(1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Reactive Power | 0.000VAR~3600kVAR | Min resolution 0.001VAR | ±(1%+3dgt) Sinφ≥0.5 |
±(1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Apparent Power | 0.000VA~9999.9kVA | Min resolution 0.001VA | ±(1%+3dgt) |
Power Factor | -1.000~ 1.000 | 0.001 | ±(1.5%+3dgt) Cosφ≥0.5 |
±(1.5%+10dgt) 0.2≤Cosφ<0.5 | |||
Phase Angle | -179°~ 180° | 0.001° | ±(2°) |
Voltage Harmonic Ratio 2-51 orders (Vrms>50V) | 0.0%~ 99.9% | 0.001% | (2~20orders)±(1%+5dgt) (21~30orders)±(1%+10dgt) (31~51orders)±(1%+15dgt) |
Voltage Harmonic Angled (Vrms>50V) | -179°~ 180° | 0.001° | ±(3°) harmonics for 2 - 25 orders |
±(10°) harmonics for 26 - 50 times | |||
Current Harmonic Ratio 2-51 orders (Arms>Irange/100) | 0.0%~99.9% | 0.001% | (2~20orders) ±(1%rdg+5dgt) (21~30orders) ±(1%rdg+10dgt) (31~51orders) ±(1rdg%+15dgt) |
Current Harmonic Angle (Arms>Irange/100) | -179°~180° | 0.001° | ±(3°) harmonics for 2 - 25 orders ±(10°) harmonics for 26 - 51 orders |
Total Harmonic Ratio (THD or THD-F)≤50 | 0.0%~ 99.9% | 0.001% | ±(1%rdg+10dgt) |
Distortion Factor (DF or THD-R)≤50 | 0.0%~ 99.9% | 0.001% | ±(1%rdg+10dgt) |
Three-phases Unbalance | 0.0%~ 100% | 0.01% | ±(1%) |
Item | Accessories | Qty |
1 | Host | 1PCS |
2 | Clamp Current Sensor | 4PCS |
3 | Pen Probe Test line(Each 1PCS of yellow,green, red and black, length 3m) | 4PCS |
4 | Alligator Clip | 4PCS |
5 | Power Adaptor(DC 12V) | 1PCS |
6 | USB Data Cable | 1PCS |
7 | 4G Memory Card | 1PCS |
8 | Manual, Warranty Card, Qualification Card | 1SET |