Description
H221 analog current
transducers provide reliable load trending information for large motor loads
(up to 300A), with a proportional 4-20mA signal. This model includes a span
potentiometer that allows each sensor to be calibrated for maximum resolution.
Split core,
amperage range: 0 to 100-300A AC adjustable, Analog output transducer: 4-20mA
output, loop powered, large size housing. UL.
APPLICATIONS
- Load trending of large motors
Monitor larger motors
and other loads up to 300A
- Split-core design for easy
installation and fast retrofits
- Eliminates need for external CTs
on large conductors
- Large openings for heavy conductors
- Monitor critical motors
(compressor, fuel, etc.)
Loop powered 4-20mA
output
- Two-wire design reduces wiring
cost
- Zero and span adjustments for
field flexibility
- 100% solid state...no moving parts
to fail
Specifications
- Sensor Power 30mA (max)@12-30VDC
- Insulation Class 600VAC RMS
- Frequency Range 50/60 Hz
- Temperature Range -15° to 60°C (5°
to 140°F)
- Humidity Range 10-90% RH,
non-condensing
- Accuracy 2% of FS from 10 to 100%
of full scale
- Response Time 2 sec.
- Zero Adjustment 3.5 to 4.5mA
- Agency Approvals UL 508 open
device listing