TLC6000 Dynamic Holter

usb pc software
pc software need to be downloaded, no disk is included
               
Introduction
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.

Function
1)Adopt 12-lead system of international standard, continuously record ECG waveform for 24-hour.
2)Sync analysis for 12-lead, and any channels can be selected as the main analysis channel, which ensures that QRS waveform can be found accurately, and no distortion.
3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
4)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
5)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function. 
6)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
7)With analysis functions for 5-minute, 1-hour and whole heart rate variability.
8)One-key print, convenient and fast to print the reports.
9)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
10)“T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
11)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.

Performance
1)Lead: standard 12-lead
2)Power supply: one “AAA” alkaline battery
3)Interface: USB2.0
4)Input impedance: ≥10MΩ
5)CMR: ≥60dB
6)Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%
7)Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.
8)System noise: ≤50µVp-p
9)Multichannel crosstalk: ≤0.2mV
10)Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.
11)Minimum measure signal: 50 µV
12)Timing accuracy: the overall error during 24h shall not exceed 30s.






Buy safe Products


The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: 
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies.
If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.

The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923, and certified by FDA of United States and CE,TUV of Europe. 
The  Fingertip Pulse Oximeter that is FDA 510K Approved





Payment

We accept payment by PayPal. PayPal enables you to make payment quickly and securely online.

1: We accept payment via PayPal.
2: Please pay the money within 5 days after the auction ended.
3: Please offer home or mobile phone when the item's Value exceeds 100 (USD, EUR, AUD, GBP) so that we can 
make sure you get the item safely.



Shipping

1). We will ship within 2 business day after your payement ;
     
     We ship the item by USPS first class service for USA buyers,you can get the item in 1-5 days.
     We ship the item by EUB(epacket) for CA,AU,UK,RU buyers.you can get the item in 10-25 days.
     We ship the item by Registered China Post Air Mail for the other buyers,you can get the item in 30-35 days.
2).We don't add taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties).

 Please find out as much as you can about your import taxes in your own country before bidding the item. You need to pay for the import duties in case

 that occurred for certain goods, or you may kindly give us some suggestions about that, we promise to do our best to help you!


About Warranty:

We guarantees new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months
 for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our 
company's option, any part which upon our company's examination proves defective.


Return Policy:

If you receive a defective item which you want to return, please contact us within 5 days from the day you receive the item. 
All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.
We will refund the money to you when we get the return items. Or replace item for you free of charge.


About us

Contec Medical Systems focusing on research, manufacture and distribution of medical instruments,was founded in 1992 
as a high-tech company.

At present there are more than 1200 employees in our company.Our product line covers a wide range of 13 categories.

Most of the domestic hospitals are our customers.

Contec hopes to cooperate with international companies to supply more innovative design and advanced technology products 

We sincerely welcome you to become one of our global partners.We are looking forward to establishing a successful business relationship with you.

If you have any questions or Dissatisfaction, please contact us via ebay message,
we will try our best to help you to solve the problem and give you satisfied answer


 
               
           

Powered by SoldEazy


We only have the English Manual in the standard package, If you need any other language Manual, please contact us freely

ibay365