This product is suitable for pharmaceutical, scientific research, chemical industry, etc. It can sterilize dressings, glassware, culture medium and so on.
The series of sterilizers are designed using the principle of killing microorganisms by moist heat. The principle is to use the principle of gravitational displacement, so that the steam in the sterilizer from the top down, the cold air from the lower vent, the discharged cold air is replaced by saturated steam, and the use of the latent heat released by the steam to make the items to achieve sterilization.
TECHNICAL PARAMETERS
|
Model |
DSX-18L-I |
DSX-24-I |
DSX-30L-I |
|
Configuration |
Semi-auto Control |
Semi-auto Control |
Semi-auto Control |
|
Material/Pot Wall Thickness |
Stainless Steel/2.0 mm |
Stainless Steel/2.0 mm |
Stainless Steel/2.0 mm |
|
Volume/GW |
18 L/16 KG |
24 L/24 KG |
30 L/32 KG |
|
Voltage/Power |
220 V/2 Kw |
220 V/2 Kw |
220 V/2 Kw |
|
Packing Size (L*W*H) |
410*410*670 mm |
500*500*800 mm |
500*500*900 mm |
|
Product size |
440*445*629 mm |
440*484*815 mm |
440*484*815 mm |
|
Use Volume (D*H) |
269*260 mm |
269*330 mm |
269*420 mm |
|
Time Setting Range |
0-999 min |
0-999 min |
0-999 min |
|
Rated Working Pressure |
0.142 Mpa |
0.142 Mpa |
0.142 Mpa |
|
Temperature Setting Range |
50-126 ℃ |
50-126 ℃ |
50-126 ℃ |
1.Intelligent microcomputer control system:Using LED digital control system; After sterilization finished, sterilizer will automatic alarm and shut down.
2.Interlock device:The control system can real time supervision the sterilizer chamber’s temperature and pressure. Only under the safety temperature and pressure can open the sterilizer’s cover. Make sure the operator’s safety.
3.The structure of cover’s opening:Using shift place type of quickopen cover to improve sealing and safety performance.
4.Memory storage system:Store the last operation program so convenient next operation.
5.Digital display screen:Digital display screen and working indicator light display running state.
6.Safety devices:Interlock device, overtemperature and over pressure protecting system, burned protection, safety relief valve, current leakage protector and automatic fault detection