LCR Meter Auto Range Resistance Component Test Equipment 0.05% Accuracy


Features

■ Low cost, high performance, small size

■ 4.3 inch TFT LCD Display

■ Soft power switch

■ Selectable Chinese-English operation language

■ Max. 200kHz test frequency

■ Max. 6 digit reading resolution

■ 10mVrms-2.0Vrms programmable signal level, built-in 0 - ± 5V/50mA bias source

■ DCR, 50mV-2V programmable test level, resolution 10μΩ

■ Ls-Rd / Lp-Rd Function (L, Rd display simultaneously) 

■ Highest test speed 13ms/time

■ Selectable 30Ω/100Ω signal source impedance 

■ V/I monitor and auto level adjustment function

■ Built-in comparator, 10 bins sorting and count function

■ File storage and firmware update through U disk

■ RS232, RS485, USB, HANDLER, GPIB interface

 

Brief Introduction

■ Adopting the latest technology & high density circuit design and concentrating the essence of LCR test, TH283X series is a new generation compact LCR meter of low cost and high performance. Instead of traditional mechanical power switch, it adopts software control power switch. The basic accuracy of 0.05% and good test stability can compare favourably with those high-end models. Being equipped with 4.3 inch TFT LCD Display and brand new interface system, TH283X series LCR meters possess elegant appearance and easy operation.

Also, being provided with various interfaces and good compatibility with SCPI commands, TH283X series LCR meters are convenient for constituting all kinds of test system and satisfy various kinds of demands for inspection, production and scientific research.

 

Specifications

ModelTH2832
Basic Measurement Accuracy
(See Details in Technical Specification)
LCRZ0.05%
DCR0.1%
Calibration Condition

Warm up time: ≥ 30 minutes;

Environment temperature: 23±5ºC 

Signal level: 1Vrms; 

Corretion: after OPEN, SHORT

Testing cable length: 0 m

Test Signal Frequency20Hz-200kHz, continuously
Signal Source Output ImpedanceSelectable 30Ω, 100Ω,  ±1% @1kHz
AC Test Signal LevelNormal10mV—2Vrms
Resolution: 10mV,Accuracy: 10% x setting voltage+2mV
100μA—20mArms
Resolution: 0.1mA
Constant level
(ALC ON)
20mV—1Vrms
Resolution: 10mVAccuracy: 10%
200μA—10mArms
Resolution: 0.1mA
DCR test signal level50mV—2V DC
Resolution: 0.5mV
DC bias voltage source0V— ± 5V
Resolution: 0.5mV,Accuracy: 1%
0mA—± 50mA
Resolution: 0.5μA
Test Parameters|Z|,Y|, C, L, X, B, R, G, D, Q, θ, DCR
DCR display range0.00001 Ω – 99.9999 MΩ
LCR Parameters Display Range

|Z|, R, X 0.00001Ω — 99.9999MΩ

|Y|, G, B 0.00001μs — 99.9999s

C 0.00001pF —  9.99999F

L 0.00001μH —  99.9999kH

D 0.00001 —  9.99999

Q 0.00001 — 99999.9

θ(DEG) -179.999º — 179.999º

θ(RAD) -3.14159 — 3.14159

Δ% -999.999% — 999.999%

Display Digits6
Measurement Time (≥10 kHz)Fast: 75 meas/sec(13ms), Medium:11 meas/sec(90 ms),
Slow: 2.7meas/sec(370 ms)
Equivalent CircuitSerial, Parallel
Range ModeAuto, Hold
Trigger ModeInternal, Manual, External, Bus
Average Time1–255
CorrectionOpen, Short, Load
Math OperationDirect reading, ΔABS, Δ%
Trigger Delay Time Setting0 - 60.000s, 1ms steps
Step Delay Time Setting0 - 60.000s, 1ms steps
List Sweep

10 points list sweep

·Frequency, AC voltage/current, internal/ external bias voltage/ current can be swept.

Each sweep point can be sorted separately.

Comparator Function10 bins, BIN1–BIN9, NG, AUX
Bin count function
PASS, FAIL LED display on front panel
Built-in StorageInternal 100 LCRZ instrument setting files, 201 times test results
USB StorageInstrument setting files , measurement result CSV files, printed screen (GIF format)
InterfaceControl InterfaceHANDLER
Communication
Interface
USB HOST, RS232C, RS485(option), GPIB(option)
Storage InterfaceUSB DEVICE (U-disk storage)