GENERAL MONITORS MSA IR5500 Open Path Source / Emitter
P/N 329001-25
Short Range Detection
Made in USA
Please see also GENERAL MONITORS MSA IR5500 Open Path IR Receiver - eBay item number: 255652940466
Please see below manufacturers general description
The Model IR5500 Infrared Open Path System is a hydrocarbon gas detector
(Figure 1). The system consists of a Source and a Receiver. Both units are
calibrated at the factory and need no further alignment. The operation of the Model
IR5500 can be checked by placing a Test Gas Film in front of the Receiver. The
system requires only a periodic cleaning of the windows to assure dependable
performance, and is recommended prior to zero check, test gas, and optical
integrity testing. The Model IR5500 Infrared Open Path System continuously
monitors hydrocarbon gases. The gas detection range of a Receiver calibrated for
methane is 0 to 5,000 ppm•m and 0 to 5 LEL•m while that for propane it is 0 to
2,000 ppm•m and 0 to 1 LEL•m. The Receiver provides two 4 to 20 mA analog
signals, one proportional to ppm•m and the other to LEL•m. Alarm and Fault
relays, split range (A/O-ppm), Modbus, and HART outputs are optional.
The Model IR5500 Infrared Open Path System is easily aligned using the digital
display and adjustable mounting arms, therefore does not require any bulky setup
equipment such as digital volt meters and handheld alignment aids. For setups that
require the distance from the Source to the Receiver to be greater than 100
meters, General Monitors offers an optical alignment scope that makes the initial
alignment easier.
The Model IR5500 Infrared Open Path System is a hydrocarbon gas detector . The system consists of a Source and a Receiver. Both units are
calibrated at the factory and need no further alignment. The operation of the Model
IR5500 can be checked by placing a Test Gas Film in front of the Receiver. The
system requires only a periodic cleaning of the windows to assure dependable
performance, and is recommended prior to zero check, test gas, and optical
integrity testing. The Model IR5500 Infrared Open Path System continuously
monitors hydrocarbon gases. The gas detection range of a Receiver calibrated for
methane is 0 to 5,000 ppm•m and 0 to 5 LEL•m while that for propane it is 0 to
2,000 ppm•m and 0 to 1 LEL•m. The Receiver provides two 4 to 20 mA analog
signals, one proportional to ppm•m and the other to LEL•m. Alarm and Fault
relays, split range (A/O-ppm), Modbus, and HART outputs are optional.
The Model IR5500 Infrared Open Path System is easily aligned using the digital
display and adjustable mounting arms, therefore does not require any bulky setup
equipment such as digital volt meters and handheld alignment aids. For setups that
require the distance from the Source to the Receiver to be greater than 100
meters, General Monitors offers an optical alignment scope that makes the initial
alignment easier.
Location: C A Sth 3
Some countries have Import Taxes and / or Charges.
Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.
Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.
These charges are normally collected by either the Customs Office, the delivering freight (shipping) company or when you pick the item up. Please do not confuse these charges for any for additional shipping charges.
We cannot mark merchandise values below the sale price or mark items as "gifts" - This is against Australian Government Law.