If you have experience in the field of tubes you can find in the photos and in the details below the testing / sorting procedure and all the results, and if you do not have the necessary experience to understand what is explained you can trust that we deliver only very good tubes.
The best method of selecting tubes in PAIR is to overlap the G1/Ia curves, the superimposed curves show us that the tubes have the same plate current and the same transconductance in the whole operating range. One point matching method used with analog tube testers is a pretty good compromise solution, but identical tubes at one point can have big differences at higher or lower currents, testing in 20÷50 points with these devices and drawing curves take hours for each tube. Roetest does this quickly and with great precision.
This is the best way to select pairs, based on overlapping curves. The tubes meet datasheet specifications, first the quality tests – filament test, shorts test, gassy test (Ig1, vacuum factor, Ia variation with 1M2 grid series resistor), kathode isolation (leakage to filament), then quantity tests – value of current for plate,G2, kathod, G1, value for transconductance, gain, G1 curve, Ia curve etc., all results for these tests can be seen on te datasheet delivered for each tube.Those who use tubes are more familiar with terms like bias, gain (µ), plate current, slope/transconductance, and maybe someone is wondering what the term „D of plate” in the measured data means. Its value in itself is not so important but it is useful to calculate the other parameters taking into account Barkhausen's tubular formula S x D x Ri = 1 (slope * penetration * internal resistance=1), where D is –dUg/dUa at Ia=const. Barkhausen vas a german physicist, he was “the guru” of tubes, his theory and formulas guided the entire period of electronic tubes.
For sale is a matched pair of 4P1L tube, 2 tubes with superimposed curves for entire range of work. Two curves superimposed means perfect match, the same plate current and transconductance for entire range, not only in ne operating point as usual test methods.
Test condition - plate and screen 150V, grid -6V, accepted only very good tubes with plate current 30-40mA and transconductance 5.2-6.2mA/V.
Tubes passed all quality test – vacuum, shorts, leaks, heater current etc.
I photos can be seen example of data and curves.
All tubes were burned about an hour before tests.
Excellent tubes, very linear, could be used in all stages (preamp, drive, and output) with very very low distortions.