K109LV allows a conversion of the signals with mV (±25 mV..±2000 mV) standard into mA/V standard signals. It’s useful for DC current monitoring through shunts. The power supply connection is available on the terminals or a special connector (K-BUS) allows a distribution of the power supply to the modules via bus connector. A 3-way galvanic isolation among Power supply // input // output circuits assures the integrity of your datas.
Features:| GENERAL DATA | |
| Power Supply | 19,2…30 Vdc |
| Power Consumtption | 500 mW |
| Isolation | 1.500 Vac (3 way |
| Power transducers | - |
| Accuracy | 0,1% |
| Response time | 25 ms |
| Status Indicators | Power supply, error |
| Setting | Dip Switches |
| Mounting | 35 mm DIN rail guide |
| Protection Degree | IP20 |
| Operating Temperature | -20..+65 °C |
| Dimension (W x H x D) | 6,2 x 93 x 102,5 mm |
| Input | |
| Channel Numbers | 1 |
| Voltage (mV) | Range: ±25, 50, 60, 75, 80, 100, 120, 150, 200, 250, 300, 400, 500, 1000, 2000 mV (via Dip switches) |
| Output | |
| Channel Numbers | 1 |
| Voltage | Range: 0..10 / 10..0 / 0..5 / 1..5 V Min load resistance: 2 kO |
| Current | Range: 4..20 / 20..4 / 0..20 / 20..0 mA Max load resistance: 500 O Protection: 25 mA |
| Standard | |
| Approval | CE |
| Norms | EN 50081-2; EN 55011; EN 50082-2; EN 61000-2-2/4; EN 50140/141; EN 61010-1 |