I made this Instructional video to help explain how this RF unit works.
https://youtu.be/kwYo0U3W8vU
2. The way
of output
A. Signal
keeps 3 seconds-- “1” connect
B. Signal
self-locking -- “2” connect
C. Signal
interlock -- “3” connect
D. Signal
point start--disconnect
(check
the Circuit diagram for details)
3. Learning
way and steps
1. Press
learning key of receiver—the pilot lamp light—release learning key and pilot
lamp extinguish , indicate enter into the status of learning.
2. Press any
button of the remote control, indicate learning success as the pilot lamp flash
5 times and automatically exit learning state. Receiver automatically exit
learning state if you do nothing in 32 seconds.
4. Delete
memory message
Press the
learning key of the receiver—pilot lamp light—hold on pressing over 8 seconds
until the pilot lamp extinguish, which indict success to delete the memory
message.
5. Main
Technique Data
Working
voltage DC12V/
Static
working current ≤7mA
Working
temperature -40℃
- +80℃
Receiving
sensitive ≥-105dBm
Working
frequency 433MHz
Relay capacity 10A 250VAC or 10A 30VDC
Receive the
type of encoding Learning code,
Fixed code, Rolling/Hoping code
Maximum
storage for transmitter 30pcs
of learning or fixed code; 6pcs of rolling code
Size 74.5mmⅹ54.5mmⅹ27mm
If you would like a FREE catalog of my eBay store, just add
a note, or send me a message, during or after check out.