X-Rite i1Pro Spectrophotometer | ΞE 0.30 (BCRA Tested) | Ready to Work
The X-Rite i1Pro (also called EFI ES-1000) is a professional-level spectrophotometer and an industry standard for calibrating monitors, printers, and proofing systems. It is suitable for any field where precise color measurement is required.
1) ICC Profiling and Calibration
Widely supported by major RIP software: EFI Fiery, Onyx, Caldera, VersaWorks, and more.
Compatible with frontends from Creo, Scitex, Barco, and others.
The spectrophotometer itself acts as a hardware dongle, so no separate physical license key is required. The licensed modules are recognized automatically by compatible software.
β i1Match Monitor β licensed
β i1Match Printer Easy RGB β licensed
β i1Match Printer Easy CMYK β licensed
Measurement Modes: [Reflectance Spot, Reflectance Scan, Emission, Ambient Light Spot, Ambient Light Scan]
Licensed functionality: [Has Ambient Light, Spectral values, Tristimulus, Density]
β i1Match 3.6 was tested and working on Windows 10 64-bit for monitor calibration and supported RGB/CMYK printer workflows.
β The instrument was also tested with i1Profiler 3.1.1 on Windows 11 64-bit for monitor calibration. See the corresponding photo in the listing.
3) Spot Color Measurement & ΞE Analysis
Π‘an be used for verifying printed color accuracy, ink consistency, and ΞE values versus Pantone, CMYK, or ISO standards.
β Compatible with ProfileMaker 5 Measure Tool (free from X-Rite).Professional optical cleaning performed.
Fully tested using X-Rite Diagnostics β all tests passed.
Accuracy verified using a set of 12 BCRA Series II ceramic tiles.
π Average accuracy: ΞE = 0.30
BCRA (British Ceramic Research Association) tiles are the global "gold standard" for spectrophotometer verification. An average ΞE of 0.30 is excellent and comparable to factory-level performance (similar to a NEW device).
πΈ Actual Photos: The unit shown in the images is exactly what you will receive.
European Union: Fast delivery via DPD or UPS (typically 5β7 business days).
Business Buyers (EU): We support Intra-Community (0% VAT) transactions. Please provide your VAT ID via the "Make Offer" comment or message before purchase.
US Buyers: Please select UPS at checkout. Standard postal shipping is currently unavailable.
Worldwide Shipping Available. Shipping cost may vary for distant destinations. Contact us for a quote and choose your preferred shipping method: standard, EMS, or UPS.
Thank you for viewing, and happy color matching!
i1Pro Tests
General Information
Date and Time: 8/6/2026 8:15:10 PM
Application version: 4.1.2.290, 32-bit
SDK version i1Pro: 4.2.3.4987
SDK version i1iO: 2.2.3.4987
SDK version i1iSis: 2.0.0.4968
SDK version ColorMunki: 1.0.3.4630
SDK version i1Display2: X-Rite, Inc. SipCal Library Ver. 7.3.7 (32 bit)
Platform: Microsoft Windows 10, 64-bit
Open instrument
Connection: Successful
Open instrument: Successful
Instrument information
Instrument inspection: Successful
Serial number i1Pro: 315651
Type: i1Pro
Revision: D
Firmware version: 503
CPLD version: 999
Dark measurement count: 2050
Lamp burning time: 3080.5 seconds
Spot measurement count: 236
Scan measurement count: 1031
Factory calibration: 8/17/2007
Spectral Module ID: 01-fa57e81000005b
Instrument Licenses
Measurement Modes: [Reflectance Spot, Reflectance Scan, Emission, Ambient Light Spot, Ambient Light Scan]
Licensed functionality: [Has Ambient Light, Spectral values, Tristimulus, Density]
Licensed Modules:
i1Match Module "Scanner": NOT licensed
i1Match Module "Monitor": licensed
i1Match Module "Printer": NOT licensed
i1Match Module "Printer RGB only": NOT licensed
i1Match Module "Printer CMYK only": NOT licensed
i1Match Module "Beamer": NOT licensed
i1Match Module "Printer Easy RGB": licensed
i1Match Module "Printer Easy CMYK": licensed
i1Match Module "Digicam": NOT licensed
i1Match Module "Editor": NOT licensed
i1Profiler Module "Display Profiling": NOT licensed
i1Profiler Module "RGB Printer Profiling": NOT licensed
i1Profiler Module "CMYK Printer Profiling": NOT licensed
i1Profiler Module "Printer QA": NOT licensed
i1Profiler Module "Advanced-Mode": NOT licensed
i1Profiler Module "Projector": NOT licensed
Button test
Button: Successful
Emission test
Emission calibration: Successful
Prepare the instrument for emission measurement
White measurement: Successful
Gray measurement: Successful
Black measurement: Successful
Red measurement: Successful
Green measurement: Successful
Blue measurement: Successful
Emission: Successful
Button test
Button: Successful
Noise Tests
Dark measurement: Successful
Noise measurements: Successful
Noise result: Successful
Reflectance test
Reflectance Spot calibration: Successful
Reflectance Spot measurement 1: Successful
Reflectance Spot measurement 2: Successful
Reflectance Spot measurement 3: Successful
Reflectance Spot measurement 4: Successful
Reflectance Spot measurement 5: Successful
Reflectance Spot measurement 6: Successful
Reflectance Spot measurement 7: Successful
Reflectance Spot measurement 8: Successful
Reflectance Spot measurement 9: Successful
Reflectance Spot measurement 10: Successful
Lamp test: Successful
Reflectance drift test: Successful
Reflectance Scan calibration: Successful
*** PASS ***
**************************
i1Pro Tests
General Information
Date and Time: 2026-08-06T20:15:10
Application version: 4.1.2.290, 32-bit
SDK version i1Pro: 4.2.3.4987
SDK version i1iO: 2.2.3.4987
SDK version i1iSis: 2.0.0.4968
SDK version ColorMunki: 1.0.3.4630
SDK version i1Display2: X-Rite, Inc. SipCal Library Ver. 7.3.7 (32 bit)
Platform: Microsoft Windows 10 (Build 26100), 64-bit
Open instrument
Connection: Successful
Open instrument '\\?\usb#vid_0971&pid_2000#5&1e9a0576&0&1#{989d6515-e122-4442-a357-751457f102a5}': Successful
Instrument information
Instrument inspection: Successful
Serial number i1Pro: 315651
Type: i1Pro
Revision: D
Firmware version: 503
CPLD version: 999
Dark measurement count: 2050
Lamp burning time: 3080.5 seconds
Spot measurement count: 236
Scan measurement count: 1031
Factory calibration: 2007-08-17
Spectral Module ID: 01-fa57e81000005b
Instrument Licences
Measurement Modes: [ReflectanceSpot, ReflectanceScan, EmissionSpot, AmbientLightSpot, AmbientLightScan]
Licensed functionality: [Has Ambient Light, Spectral values, Tristimulus, Density]
Licensed Modules:
i1Match Module "Scanner": NOT licensed
i1Match Module "Monitor": licensed
i1Match Module "Printer": NOT licensed
i1Match Module "Printer RGB only": NOT licensed
i1Match Module "Printer CMYK only": NOT licensed
i1Match Module "Beamer": NOT licensed
i1Match Module "Printer Easy RGB": licensed
i1Match Module "Printer Easy CMYK": licensed
i1Match Module "Digicam": NOT licensed
i1Match Module "Editor": NOT licensed
i1Profiler Module "Display Profiling": NOT licensed
i1Profiler Module "RGB Printer Profiling": NOT licensed
i1Profiler Module "CMYK Printer Profiling": NOT licensed
i1Profiler Module "Printer QA": NOT licensed
i1Profiler Module "Advanced-Mode": NOT licensed
i1Profiler Module "Projector": NOT licensed
Button Test
Button: Successful
Emission test
Emission calibration: Successful
Prepare the instrument for emission measurement
White measurement: Successful (X=110.895 Y=116.135 Z=116.032)
Gray measurement: Successful (X=39.555 Y=40.221 Z=41.117)
Black measurement: Successful (X=0.108 Y=0.084 Z=0.090)
Red measurement: Successful (X=66.530 Y=31.645 Z=0.197)
Green measurement: Successful (X=29.384 Y=82.903 Z=5.544)
Blue measurement: Successful (X=20.659 Y=6.859 Z=115.084)
Emission: Successful
Button Test
Button: Successful
Noise Tests
Dark measurement: Successful (dark noise: -189.493)
Noise measurements: Successful
Noise result: Successful (electronic noise: 2.755)
Reflectance test
Reflectance Spot calibration: Successful (Restored standard lamp conditions, slope=0.250707209 (0.150000006))
Reflectance Spot measurement 1: Successful (95.767, -0.327, 2.691)
Reflectance Spot measurement 2: Successful (95.770, -0.333, 2.701)
Reflectance Spot measurement 3: Successful (95.797, -0.337, 2.704)
Reflectance Spot measurement 4: Successful (95.793, -0.331, 2.709)
Reflectance Spot measurement 5: Successful (95.801, -0.335, 2.704)
Reflectance Spot measurement 6: Successful (95.798, -0.336, 2.713)
Reflectance Spot measurement 7: Successful (95.813, -0.340, 2.694)
Reflectance Spot measurement 8: Successful (95.805, -0.331, 2.697)
Reflectance Spot measurement 9: Successful (95.793, -0.324, 2.710)
Reflectance Spot measurement 10: Successful (95.808, -0.333, 2.700)
Lamp test: Successful (minL=95.767 meanL=95.795 MIT=0.0109938411 CIT=0.01095 LOT=3129.20288)
Reflectance drift test: Successful (0.015)
Reflectance Scan calibration: Successful (slope=0.250707209 (0.150000006))
*** PASS ***