BioLabTek eBay Template
BioLabTek

pH Meter

Hanna HI5221-01 Benchtop pH Meter Laboratory ORP Temperature Tester HI 5221

Precision Research Grade Lab Instrument • High Resolution Color Display • USB Data Output

No probe stand

QC PASS Tested & Working

At a glance

Manufacturer
Hanna Instruments
Model
HI5221 Laboratory Research Grade Benchtop pH/mV
Part / Catalog #
HI5221-01
Serial #
07430071
Year / DOM
July 2024
Condition
Used, Excellent, Needs Fresh Calibration

What's Included

  • Hanna Instruments HI 5221 Benchtop pH Meter (Main Unit)
  • Hanna HI1332 Plastic Body pH Electrode
  • Hanna HI7662-W Stainless Steel Temperature Probe
  • 12Vdc Power Supply Adapter (115V US Plug)
  • Nothing else is included unless shown in the photos

Condition & Testing

Powers on and reads live pH/temp, but displays a "Factory calibration data expired" at startup ; Instrument calibration is the buyer's responsibility.

Specifications

Range (pH)-2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH
Range (mV)±2000.0 mV
Temperature range-20.0 to 120.0 °C / -4.0 to 248.0 °F / 253.2 to 393.2 K
Resolution (pH)0.1 pH / 0.01 pH / 0.001 pH
Resolution (mV)0.1 mV
Resolution (temperature)0.1 °C / 0.1 °F / 0.1 K
Accuracy at 25 °C / 77 °F (pH)±0.1 pH / ±0.01 pH / ±0.002 pH ±1 last significant digit
Accuracy at 25 °C / 77 °F (mV)±0.2 mV ±1 last significant digit
Accuracy at 25 °C / 77 °F (temperature)±0.2 °C / ±0.4 °F / ±0.2 K
Relative mV offset range±2000.0 mV
pH calibrationUp to five points calibration, 8 standard buffers available (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and 5 custom buffers
Temperature user calibration3 points (0, 50, 100 °C)
Input channel1 pH/mV
Temperature compensationManual or Automatic
GLPElectrode offset / slope, calibration points, calibration time stamp, date, time and buffers/standards used
Logging recordUp to 100 lots, 50,000 records max/lot / maximum 100,000 data points/channel
Logging interval14 selectable between 1 second and 180 minutes
Logging typeAutomatic, Manual and Auto Hold
pH electrodeHI1131B
Temperature probeHI7662-W
PC interfaceOpto-isolated USB
Input impedance10¹² Ω
DisplayColor Graphic LCD (240 x 320 pixels)
Power supply12 Vdc adapter
Environment0 - 50 °C / 32 - 122 °F / 273 - 323 K max. 95% RH non-condensing
Dimensions160 x 231 x 94 mm (6.3 x 9.1 x 3.7")
Weight1.2 kg (2.6 lbs.)

Specs from manufacturer literature for reference. Verify against your application.

Terms & Conditions

Payment

  • We accept most payment types and work with your organization's accounting requirements.
  • Contact us if you need a formal quote or to procure with a PO.

Shipping

  • Items ship within 1 to 2 business days after cleared payment.
  • We ship via USPS, FedEx, UPS, or freight, to the contiguous USA and worldwide.
  • Worldwide buyers are responsible for customs and duty import charges.
  • Need expedited service or billing to your own FedEx or UPS account? Tell us at purchase.
  • You may arrange your own shipping through your own carrier on request.

Return Policy

  • 60-day returns on all products from time of delivery.
  • If anything is not right, contact us first. We want you fully satisfied.

Why BioLabTek

  • We power on and function-test, then document what we saw
  • Photos show the exact unit you receive
  • Instruments packed to survive the carrier
  • POs and formal quotes welcome for academic and corporate buyers
BioLabTek  |  Scientific Equipment Specialists  |  © 2026 BioLabTek