WHEATON® SAFE-GRIND® Potter-Elvehjem Tissue Grinder, 2 mL
(single set, complete)



Comes from a Midwest research university.

From manufacturer:
Tissue grinders produce homogenates by a combination of shearing and compression actions. The tissue sample is progressively ground (sheared) into smaller pieces at the rounded end of the pestle as the spinning pestle is lowered into the tube. As the pestle is forced lower into the tube, the sample is displaced and forced between the straight outside wall of the pestle and the inside wall of the tube, compressing the tissue cells until they rupture. When the tube is pulled away from the pestle, a slight vacuum is created that pulls the sample back past the compression area, resulting in an additional homogenization stroke. The degree of homogenization is controlled by the clearance between the pestle’s and tube’s cylindrical section, the rotational speed of the pestle, and the number of compression strokes made. The Potter-Elvehjem tissue grinder has rounded shape on the lower portion of the pestle where th sample is progressively ground smaller. Ground glass pestle versions are suited for connective tissues whereas PTFE pestle versions are used with softer tissues.

  • Manufactured from borosilicate glass 3.3
  • Exterior plastic coated glass mortar provides greater safety during power homogenization
  • PTFE pestle tip with 6.3mm diameter stainless steel rod can be used with power homogenization for soft tissue such as brain or liver
  • Components are interchangeable eliminating need to keep parts matched during cleaning
  • Unit can be autoclaved / sterilized to prevent cross contamination between samples
  • Pestle clearance range: 0.1 – 0.15mm
  • Pestle clearance range: 0.1 – 0.15mm

  • DISCLAIMER: Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment. The purchaser, by buying this equipment, indicates their acknowledgment of, and agreement to the terms of this disclaimer.

    RETURNS: Returns are only accepted when in the same condition as sold. Items that were listed still in the original packaging can be returned only if the packaging has not been opened. In cases where the item was damaged in the mail, notification must be given upon receipt, and damaged package must be retained for possible carrier inspection. Refund will be given for purchase price only. Buyer is responsible for all shipping costs.

    SHIPPING In cases where an item is damaged in the mail, notification must be given upon receipt, and damaged package must be retained for possible carrier inspection. The following pictures are needed for us to submit an insurance claim: all damage to the item(s), the shipping box (overall and any damage to box), the shipping label, all packing material (bubble wrap, foam, paper, cardboard, etc). Without these pictures you will not be issued a refund. Shipping carrier may be switched if this is believed to be in the buyer's best interest.