Item:
1 pcs. new ABB Contactor UA95-30-11 110-115V 50Hz / 115-127V 60Hz in factory packaging!
Condition:
New, unused & in factory packaging!
Item from warehouse liquidation - packaging might have traces of storing!
Item number:
1SFL431022R8911 | UA95-30-11 | UA95-30-11-89 | 7320500250204
Item description:
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 1
Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Main Circuit 50/60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A
Rated Operational Current AC-1 (Ie):
(690 V) 55 °C 135 A
(690 V) 40 °C 145 A
(690 V) 70 °C 115 A
Rated Operational Current AC-3 (Ie):
(1000 V) 55 °C 30 A
(690 V) 55 °C 65 A
(220 / 230 / 240 V) 55 °C 96 A
(415 V) 55 °C 96 A
(440 V) 55 °C 93 A
(380 / 400 V) 55 °C 96 A
(500 V) 55 °C 80 A
Rated Operational Power AC-3 (Pe):
(500 V) 55 kW
(1000 V) 40 kW
(690 V) 55 kW
(220 / 230 / 240 V) 25 kW
(380 / 400 V) 45 kW
(440 V) 55 kW
(415 V) 55 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
Short-Circuit Protective Devices: gG Type Fuses 160 A
Rated Short-time Withstand Current (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
Maximum Electrical Switching Frequency:
AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
Rated Operational Current DC-1 (Ie):
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-3 (Ie):
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Operational Current DC-5 (Ie):
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
Rated Insulation Voltage (Ui):
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Mechanical Durability: 10 million
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? = 70 °C) °C
Rated Control Circuit Voltage (Uc):
60 Hz 115 … 127 V
50 Hz 110 … 115 V
Coil Consumption:
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 22 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A
Operate Time:
Between Coil Energization and NO Contact Closing 10 ... 25 ms
Between Coil De-energization and NO Contact Opening 10 ... 18 ms
Between Coil De-energization and NC Contact Closing 7 ... 15 ms
Between Coil Energization and NC Contact Opening 7 ... 22 ms
Connecting Capacity Main Circuit:
Flexible with Cable End 2x6…35 mm²
Bar 30 mm²
Rigid 1x10…95 mm²
Connecting Capacity Auxiliary Circuit:
Solid 2x1…4 mm²
Flexible with Insulated Ferrule 2x0.75…2.5 mm²
Stranded 2x1…4 mm²
Flexible 1x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Connecting terminals (delivered in open position) Main poles: M8 hexagon socket screw with single connector
Terminal Type: Cable Clamp
Product Net Width: 102.0 mm
Product Net Depth: 123.5 mm
Product Net Height: 148.0 mm
Product Net Weight: 2.040 kg
* A VAT-free, intra-Community delivery requires a valid UST-ID / VAT-ID. Without your UST-ID, the invoice is generated with a normal tax rate. Subsequent processing is then no longer possible! After receipt of the goods we need a confirmation of arrival, otherwise the taxes will be billed subsequently. We expect the confirmation of arrival within 2 weeks after receipt of the goods. Please send the confirmation of arrival to our customer service.