TECHNICS SH-9020 RARE Peak Average VU Meter Unit Vintage 1977 Refurbished Good Look
Technics SH-9020
Peak Average Meter Unit (1977-81)
The Technics SH-9020 is a high-precision analog peak and average measurement unit, manufactured by Technics between 1976 and 1981. Designed to be integrated into professional high-fidelity systems, it allows you to monitor signal levels with great accuracy at different points of an audio chain. The following are the most relevant technical specifications:
Description
Technics developed the SH-9020 peak/average meter unit to give you the signal and output information you need to make absolutely sure your components are delivering the high fidelity performance that you demand.
The SH-9020 functions in three modes: Peak, with an unheard of attack time of 100psec, Peak Hold, and Average at a level of performance way above VU meter industry standards.
With this capability, you can expect to realize a degree of high fidelity sound reproduction that until now existed mostly in theory.
Technical Specifications
• Operating modes: Peak, Peak Hold, and Average.
• Inputs:
• Input 1 & 2: 20 dBm (7.75 V) / 47 kΩ (0 dB sensitivity); 0 dBm (0.775 V) / 47 kΩ (+20 dB sensitivity).
• Input 3: 100 W / 10 kΩ (0 dB sensitivity); 1 W / 10 kΩ (+20 dB sensitivity).
• Sensitivity selector: 0 dB and +20 dB.
• Measurement range: from +10 dB to -50 dB.
• Indication accuracy:
• Inputs 1 & 2: ±1.5 dB.
• Input 3: ±2 dB.
• Frequency response:
• 10 Hz to 20 kHz ±1.5 dB (between +10 and -40 dB).
• 10 Hz to 10 kHz ±3 dB (below -40 dB).
• Response times:
• Attack time:
• Average: 330 ms.
• Peak and Peak Hold: 100 μs.
• Recovery time:
• Average: 250 ms (from 0 dB to -20 dB).
• Peak: 750 ms (from 0 dB to -20 dB).
• Peak Hold: retains peak for at least 25 minutes (from 0 dB to -3 dB).
• Power supply: AC 110/120/220/240 V, 50/60 Hz.
• Power consumption: 14 W.
• Dimensions: 450 mm (W) × 92 mm (H) × 378 mm (D).
• Weight: 5.6 kg.
⸻
🧩 Key Features
• Display modes: Allows switching between peak, peak hold, and average level monitoring, offering flexibility in signal observation.
• High accuracy and speed: With a 100 μs attack time in peak mode, it is extremely responsive to fast transients.
• Wide measurement range: Covers from -50 dB to +10 dB, suitable for various audio applications.
• Professional design: Part of the Technics “Professional” series, alongside the SU-9070 preamplifier and SE-9060 amplifier.