This seller is currently away until Feb. 15, 2016, and is not processing orders at this time. You can add this item to your watch list to purchase later.




If you prefer to buy an old model sensor, please check the link:

http://www.ebay.ca/itm/231690668533?ssPageName=STRK:MESELX:IT&_trksid=p3984.m1555.l2649



Range: AC-75A RMS, DC-100A

Epoxy bonded 

insulation vanish coating


Q & A:


1. Q: What types of current can be measured?

     A: DC, AC(up to several KHz) , PWM


2. Q: What is the reading out of this sensor?

     A: DC voltage,the range is from 0 - Vcc 

         * Vcc : 4.5 V -- 6 V


3. Q: How do I convert the voltage reading to the unknown current value?

     A: Formula: Unknown Current (A) = (V1-V0) / CF

          e.g. V0 = 2.5 V , CF = 0.0224

          V1 is the volt reading @ unknown current    

             

         Example 1:

         V1=3.5 V

         Unknown Current (A) = (3.5-2.5) / 0.0224 = 44.64 A

         

         Example 2:

         V1=2.0 V

         Unknown Current (A) = (2.0-2.5) / 0.0224 = -22.32 A


4. Q: What are V0 and CF?

     A: V0 is the output voltage at 0 Amp

          CF is increase of volt reading when the current increase 1 Amp

       *  All sensors will be shipped along with calibrated values of V0 and CF   

        

5. Q: How can I measure V0 and CF?

     A: To measure V0:

          Power on the sensor and read the output voltage while no current is 

          applied. This voltage is V0.

          To measure CF:

          While applying some current(e.g. 20 amp)  to sensor (passes through 

          the toroid core), read the output  voltage V1. The CF can be calculated using 

          the formula: CF=(V1-V0) / 20


Sample of Test Report 1 :(Output: Voltage Meter Reading@ Input: DC Current)

S/N:  #053101

2.500 V @ 0 Amp, 

2.714 V @ 10 Amp, 

2.926 V @ 20 Amp,

3.139 V @ 30 Amp, 

3.353 V @ 40 Amp,

3.567 V @ 50 Amp,

3.780 V @ 60 Amp, 


V0 = 2.50 V

CF = 0.021 V / Amp


Package included:

1 pcs Hall Effect Current Sensor 

Test Report


For DC Current Sensor, 4-20 mA Current Loop Transmitter,please refer to:

http://www.ebay.com/itm/Hall-Effect-100-Amp-DC-Current-Sensor-4-20-mA-Current-Loop-Transmitter-/231125885258?pt=LH_DefaultDomain_2&hash=item35d02d214a 

 

For measuring DC or AC voltage, please refer to:

http://www.ebay.ca/itm/DC-AC-VOLTAGE-TRANSFORMER-ISOLATING-HALL-EFFECT-ARDUINO-COMPATIBLE-/231069056757?pt=LH_DefaultDomain_2&hash=item35ccc9fef5


Shipping:


We ship your orders within 1-2 business days after the payment cleared.

We always offer combined shipping discounts for multiple items. Final combined shipping rates will depend on item weight and dimensions.


Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying.