INBUYING® — 110V Dust-Free Room Workshop | Cleanroom Booth 020232
INBUYING® Model 020232 110V · 200W · 99.99% @ 0.3 µm Limited stock — contact for lead time

INBUYING® Cleanroom Booth · 020232
Dust-Free Workshop · Packaging-Ready

Stop dust before it reaches the film.

A portable ISO Class 5 clean booth for stretch-film wrapping, precision assembly and inspection — where a single charged particle on the film surface can turn a passed QC batch into a field failure.

99.99%0.3 µm particle isolation
200WContinuous operation
40–60%Of traditional cleanroom cost
110V Dust-Free Room Workshop — cleanroom booth front view

Model 020232 · 110V / 60 Hz · Aluminum zinc frame

Where it earns its keep

Three jobs, one enclosure.

The booth is not a general-purpose cleanroom. It is a local contamination barrier placed exactly where hands, film and components meet.

Cleanroom booth interior used as a stretch-film wrapping station
Scenario 01

Stretch-film wrapping station

Wrap finished parts or small pallet loads inside the booth. The downward laminar flow keeps airborne dust from settling on the film as it unrolls.

Why it matters: standard stretch film builds static charge during unwind and acts as a dust magnet. Wrapping inside filtered airflow removes the particles before they become embedded in the cling layer.

Precision assembly inside a portable clean booth
Scenario 02

Precision assembly & bonding

Optical components, connectors and adhesive-bonded assemblies that reject fiber debris. The booth creates a local Class 100 envelope around the bench without conditioning the whole room.

Why it matters: human occupants shed between 100,000 and 30,000,000 particles ≥ 0.3 µm per minute. Local filtration intercepts that shed before it lands on the work.

Inspection and sampling inside a dust-free booth
Scenario 03

Inspection, sampling & rework

Open a unit for inspection or rework without exposing it to the general factory atmosphere. The booth gives you a controlled zone at the point of intervention.

Why it matters: a returned part that fails “no fault found” often picked up contamination during handling — not in the field.

The contamination chain

Dust does not need a hole to get in. It needs a surface.

In film wrapping, the film itself is the surface. The diagram below compares an uncontrolled wrapping bench with the same bench inside the booth.

Uncontrolled bench

1 Ambient air carries fibers and particles across the work surface.
2 Stretch film unwinds and builds static charge.
3 Charged film attracts dust; particles bond to the cling layer.
4 Contamination is sealed in — invisible on the pallet, visible in the field.

Inside Booth 020232

1 HEPA-filtered air is delivered as a downward laminar flow.
2 Particulate is intercepted at the filter — 99.99% at 0.3 µm.
3 Airflow continuously sweeps the wrapping zone.
4 Film is wrapped before contamination can settle.
ISO Class 5 reference: maximum 10,200 particles ≥ 0.3 µm per m³ (cumulative count, ISO 14644-1). Booth filtration is rated 99.99% at 0.3 µm — the same efficiency used to define HEPA H14 performance.
Decision support

Portable booth, fixed cleanroom, or nothing.

A clean booth controls a selected area rather than the whole room. That is the entire economic argument — and the entire operational argument.

Decision factor Booth 020232 Fixed cleanroom Uncontrolled bench
Capital cost Lower — typically 40–60% of a traditional cleanroom High — HVAC, ductwork, construction None
Installation time Short — prefabricated, modular Weeks to months Immediate
Mobility Relocatable — move to the work Fixed location Fixed location
Contamination control at film unwind Local laminar flow + HEPA Yes, if the whole room is rated No — dust settles freely
Operating cost 200W — low continuous draw High — whole-room air handling None, but quality losses are hidden
Best fit Packaging stations, assembly cells, inspection points Whole-facility GMP / semiconductor fab Non-critical work only
Specifications

Product parameters.

Voltage
110V / 60 Hz
North American standard input
Power
200 W
Low continuous operating consumption
Package size
26″ × 28″ × 18″
Shipped as one package
Weight
76.5 lbs
Frame and fan module included
Material
Aluminum zinc · aluminum leaf fan
Rust-resistant frame construction
Efficiency
99.99% of 0.3 µm particulate isolated
From ambient air inside the enclosure
Engineering decisions

Built for continuous use, not occasional demonstration.

01

Extremely low operating power consumption

Effective cost reduction across long shifts — 200W is a small fraction of the energy a conditioned room would require.

02

Built-in air duct diversion system

Reduces noise, increases fan service life and improves fan efficiency by guiding airflow instead of letting it recirculate chaotically.

03

Multi-wing centrifugal fan

Provides high air volume and high static pressure conditions, ensuring use in different environments — including film-wrapping stations with restricted intake.

04

Modular, line-ready design

Suitable for assembling ultra-clean production lines. One or more sets can be configured according to process requirements, or connected in series to form a Class 100 assembly line.

What the numbers mean

Claims you can verify against the standard.

ISO Class 5
Particle concentration target: ≤ 10,200 particles ≥ 0.3 µm per m³ (ISO 14644-1, cumulative).
HEPA H14 equivalent
99.99% filtration efficiency at the most penetrating particle size (0.3 µm).
Aluminum zinc frame
No rust, no dust shedding from the structure itself — the enclosure does not become a particle source.
Installation

See the assembly before you commit.

Two walkthroughs, recorded on the actual unit. Links open YouTube in a new tab.

Setup

Filter placement.

Correct orientation is the difference between 99.99% and a false sense of protection.

Filter placement diagram — view 1
Filter placement diagram — view 2
Quick-start tutorial

From crate to clean airflow.

Step 01

Position the frame

Place the aluminum zinc frame on a flat surface near the packaging or assembly point. Lock the casters if the floor is uneven.

Step 02

Install panels & fan module

Fit the panels, then seat the multi-wing centrifugal fan module on the top opening. Confirm the gasket is fully seated.

Step 03

Place the HEPA filter

Insert the filter in the orientation shown in the diagrams above. The gasket side faces the airflow outlet — a reversed filter leaks unfiltered air.

Step 04

Power and verify airflow

Connect 110V / 60 Hz. Confirm downward airflow across the work zone before bringing in film or components.

Stock note: Model 020232 is a specialized 110V configuration. Inventory moves in small batches, and lead time can extend when a batch is allocated to a single assembly-line project. If your process window is tight, confirm availability before placing the order.

Small-batch inventory

Shipping & Handling

  • Coverage. Default shipping cost or free shipping service is only available for eligible addresses within Canada via UPS Standard. For other areas or alternative shipping methods, please contact us.
  • Warranty. 6 months' warranty on the machines — not on consumables. We stand behind our products, so even after your warranty period has expired you can still seek service or technical support from us at low cost.
  • Handling time. Shipping is usually made within 1–3 business days after payment clears. Orders are processed Monday–Friday; not on weekends or public holidays.
  • Sales tax / customs duties. Collected by eBay.

Return & Refund

  • Returns & exchanges. All returns should be made within 30 days of delivery date. Items must be in unused condition, with all original materials included. A partial refund may be applied for opened or damaged items, depending on the condition.
  • Buyer's remorse. Return shipping must be covered by the buyer; original shipping cost is deducted from the refund. A 15–30% restocking fee of the item purchase price applies.
  • Defective or damaged products. If a product was received damaged or not as described, please send us pictures or videos so we can understand the problem and solve it ASAP. It also helps us claim with UPS and reminds our packaging team to pay closer attention.
Before you decide

Frequently asked questions.

Is this a full cleanroom or a local clean zone?

It is a local clean zone — a clean booth. It controls the air inside the enclosure, not the entire room. That is why it costs a fraction of a fixed cleanroom and can be moved to the work. For stretch-film wrapping, assembly and inspection, local control is often the correct scope.

How does the booth help with stretch film specifically?

Stretch film generates static charge as it unwinds, and charged film attracts dust, fibers and fine particles. Inside the booth, the downward HEPA-filtered airflow continuously sweeps the wrapping zone, so particles are intercepted before they settle on the film surface. The film goes on clean and stays clean under the cling layer.

What does 99.99% at 0.3 µm actually mean?

It is the filtration efficiency at the most penetrating particle size for HEPA-class media: 99.99% of particles at 0.3 µm are captured. In ISO Class 5 terms, the allowable concentration at 0.3 µm is 10,200 particles per m³ (cumulative). The booth is designed to create that local condition — not to certify an entire building.

Can I connect multiple units into a line?

Yes. The modular design allows one or more sets to be configured according to process requirements, or connected in series to form a Class 100 assembly line. Each unit has its own fan and filter, so a single unit can be taken offline without shutting down the whole line.

What is not covered by the 6-month warranty?

Consumables — notably the HEPA filter — are not covered, because filter life depends on ambient particle load and operating hours. The fan, frame, panels and electrical components are covered for 6 months. After that, service and technical support remain available at low cost.

Other cleanroom models and configurations
Beyond 020232

We have other models of machines.

If your process requires a different footprint, a different voltage, or a larger multi-unit line, our customer service can match the configuration. The 020232 is the 110V packaging/assembly configuration shown here; other models are available on request.

If you need, please contact our customer service before ordering to confirm the correct model for your line.

Datacaciques